Atomic force microscopy observation of insulated molecular wire formed by conducting polymer and molecular nanotube
Journal of Chemical Physics, ISSN: 0021-9606, Vol: 116, Issue: 5, Page: 1753-1756
2002
- 119Citations
- 30Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
Inclusion complex formation between the conducting polymer, polyaniline (PANI), and the molecular nanotube was studied by atomic force microscopy (AFM). The AFM observation showed rodlike structures on a mica substrate where the mixture of PANI and the molecular nanotube was spin-coated at room temperature. From the length and height of the structure, it was identified with the inclusion complex between PANI and the molecular nanotube. PANI was fully covered by the molecular nanotubes. The long persistence length of the inclusion complex indicated that PANI formed trans configuration owing to confinement in the very small cavity of the molecular nanotube.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know