0.9 T static magnetic field and temperature-controlled specimen environment for use with general-purpose optical microscopes
Review of Scientific Instruments, ISSN: 0034-6748, Vol: 77, Issue: 1, Page: 1-4
2006
- 5Citations
- 11Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
We describe the addition of a simple, low-cost 0.9 T fixed magnetic field to a commercially available, variable-temperature sample environment suitable for optical microscopy. The magnetic field is achieved with the use of Fe-Nd-B rare-earth permanent magnets and steel yoke assembly, packaged into a Linkam Scientific Instruments model THMS600 heating and cooling stage. We demonstrate its effectiveness with examples of magnetic ordering of a lipid/water system doped with paramagnetic Tm ions in the presence and absence of the applied magnetic field and at different temperatures. © 2006 American Institute of Physics.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know