Measurement of ion induced damage-profiles in GaAs
Journal of Applied Physics, ISSN: 0021-8979, Vol: 74, Issue: 11, Page: 6587-6591
1993
- 10Citations
- 2Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
In this study, with the use of a sensitive optical technique, we demonstrate the possibility of measuring the depth distribution of damage in GaAs that is generated by various ion-assisted processes such as ion implantation and ion assisted plasma etching. We have used this technique to measure the depth distribution of damage in both He and Ar implanted GaAs and in inert gas and reactive ion etched GaAs. The sensitivity of the technique allowed us to measure damage profiles over a large range of ion energies and ion doses. We have also confirmed previously published results indicating that damage created by sputter etching is inversely proportional to the mass of the ions used in the etching process.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know