Noncontact technique for measuring the electrical resistivity and magnetic susceptibility of electrostatically levitated materials
Review of Scientific Instruments, ISSN: 0034-6748, Vol: 83, Issue: 10, Page: 103907
2012
- 14Citations
- 17Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Conference Paper Description
We describe the development of a new method for measuring the electrical resistivity and magnetic susceptibility of high temperature liquids and solids. The technique combines a tunnel diode oscillator with an electrostatic levitation furnace to perform noncontact measurements on spherical samples 2-3 mm in diameter. The tank circuit of the oscillator is inductively coupled to the sample, and measurements of the oscillator frequency as a function of sample temperature can be translated into changes in the samples electrical resistivity and magnetic susceptibility. Particular emphasis is given on the need to improve the positional stability of the levitated samples, as well as the need to stabilize the temperature of the measurement coil. To demonstrate the validity of the technique, measurements have been performed on solid spheres of pure zirconium and low-carbon steel. In the case of zirconium, while absolute values of the resistivity were not determined, the temperature dependence of the resistivity was measured over the range of 640-1770 K and found to be in good agreement with literature data. In the case of low-carbon steel, the ferromagnetic-paramagnetic transition was clearly observable and, when combined with thermal data, appears to occur simultaneously with the solid-solid structural transition. © 2012 American Institute of Physics.
Bibliographic Details
AIP Publishing
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know