Highly compact and easy-to-use optical chip interferometer with picometric performances
Review of Scientific Instruments, ISSN: 1089-7623, Vol: 87, Issue: 10, Page: 103103
2016
- 4Citations
- 15Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations4
- Citation Indexes4
- CrossRef4
- Captures15
- Readers15
- 15
Article Description
In this paper, we present a compact, inexpensive, and easy-to-use optical chip interferometer based on the telecom integrated waveguide technology. The measurement evaluation is focused on the resolution and the noise level of the sensor. The power spectral density of 100 fm Hz @ 10 kHz is reached in static conditions. The same level is obtained with the standard Allan deviation for both short and long term measurements. Dynamic performances are also evaluated with sub-nanometer measurements made with piezoelectric systems. The potential bandwidth of the sensor is very high and is currently only limited by electronics (250 kHz).
Bibliographic Details
AIP Publishing
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know