An electron-ion coincidence spectrometer for commissioning of a synchrotron radiation beamline: Absolute photon intensity and content of higher harmonic radiation
Review of Scientific Instruments, ISSN: 1089-7623, Vol: 94, Issue: 5
2023
- 4Citations
- 3Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
We describe the commissioning of a new electron-ion coincidence spectrometer used to diagnose the photon beam from a plane grating monochromator beamline at the ASTRID2 synchrotron radiation facility. The spectrometer allows determination of the absolute photon intensity by calibration to the photoabsorption cross sections of known gases, such as the rare gases Ar, Kr, and Xe presented here. The spectrometer operates at very low pressure (∼10-10 mbar) and—due to the coincidence electron-ion detection scheme—the detector efficiencies can be determined routinely; hence, the spectrometer can be recalibrated swiftly. By variation of a single potential of the spectrometer, the content of higher order radiation in the monochromatized synchrotron radiation can be analyzed. The layout and operation of the synchrotron radiation beamline at ASTRID2 and its additional photon diagnostic units are additionally described.