Influence of Helmholtz oscillations on arc voltage fluctuations in a dc plasma spraying torch
Journal of Physics D: Applied Physics, ISSN: 0022-3727, Vol: 40, Issue: 23, Page: 7357-7366
2007
- 62Citations
- 25Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
Arc voltage fluctuations are studied for two different plasma torches. One of them is home-made, the other is a Sultzer Metco plasma torch. Both work under similar operating conditions, but they show very different voltage waveforms and spectra, depending on their electrode configurations. The first torch shows a rather intermittent behaviour and works under the restrike mode with a rather low fluctuation amplitude and with non-reproducible spectral components. The second torch also shows characteristic features related to the restrike mode, but they are superimposed on more regular oscillations which are due to pressure variations in the cold gas chamber, located upstream the arc region. This part of the torch together with the nozzle channel appears to be a Helmholtz resonator, whose resonance frequency is theoretically evaluated as a function of the torch geometry and of the operating conditions. The theoretical predictions are in very good agreement with the measured frequency of the main peak in the voltage spectrum of the second torch. A discussion about the coupling between the pressure and the voltage is proposed to explain how the torch design could influence the Helmholtz resonance. © 2007 IOP Publishing Ltd.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=36349017134&origin=inward; http://dx.doi.org/10.1088/0022-3727/40/23/016; https://iopscience.iop.org/article/10.1088/0022-3727/40/23/016; http://stacks.iop.org/0022-3727/40/i=23/a=016/pdf; https://dx.doi.org/10.1088/0022-3727/40/23/016; https://validate.perfdrive.com/9730847aceed30627ebd520e46ee70b2/?ssa=88152eb2-710d-4546-af9f-8b6524682e84&ssb=53310241133&ssc=https%3A%2F%2Fiopscience.iop.org%2Farticle%2F10.1088%2F0022-3727%2F40%2F23%2F016&ssi=fa226fa5-cnvj-4582-aab6-a109a2035afc&ssk=botmanager_support@radware.com&ssm=63139025193169447173238120383316054&ssn=c11249da177620d7fbe8e30830b225c6384fe6de3031-b8c3-4fbb-a852fb&sso=784bccc8-339afdbf16e2ce478d78ff2a07bee6eac3cd6044007eecbe&ssp=19031726721738453865173855869762282&ssq=92076219118294130963308198036591458510932&ssr=NTIuMy4yMTcuMjU0&sst=com.plumanalytics&ssu=&ssv=&ssw=&ssx=eyJyZCI6ImlvcC5vcmciLCJfX3V6bWYiOiI3ZjYwMDBlNDViMGUyMS0yNzYwLTRlMGYtOGM5My04OTJlMDRhODAyOWYxNzM4NDA4MTk4NTU1MTgyOTg0MzkwLWY0MjI3MTQ5ZmRjOTljNTgxNzMyMyIsInV6bXgiOiI3ZjkwMDA3NGVkZTk5OC00MTBhLTRlNTctYjZkYi00ODhiMmI0NjhlYzMzLTE3Mzg0MDgxOTg1NTUxODI5ODQzOTAtNzE0YTIxZDBhMGNhOWZkZDE3MzIzIn0=
IOP Publishing
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know