Performance evaluation of a CyberKnife® G4 image-guided robotic stereotactic radiosurgery system

Physics in Medicine and Biology, ISSN: 0031-9155, Vol: 53, Issue: 17, Page: 4697-4718
2008
  • 122
    Citations
  • 0
    Usage
  • 116
    Captures
  • 79
    Mentions
  • 0
    Social Media
Metric Options:   Counts1 Year3 Year

Metrics Details

Most Recent News

New England Journal Of Medicine Study Reaffirms Five Session Radiation Treatment Provides Comparable Rates Of Cancer Control, Tolerability And Sexual Functioning To Conventional Radiotherapy Treatment In Men With Localized Prostate Cancer

Link to Story The Precision of Stereotactic Body Radiation Therapy (SBRT), an Advanced Treatment Technique, Enables Treatment in Five Days, Significantly Reducing the Time Men

Article Description

The aim of the current work was to present the performance evaluation procedures implemented at our department for the commissioning of a G4 CyberKnife system. This system consists of a robotic manipulator, a target-locating system and a lightweight 6-MV linac. Individual quality assurance procedures were performed for each of the CyberKnife subsystems. The system was checked for the mechanical accuracy of its robotic manipulator. The performance of the target-locating system was evaluated in terms of mechanical accuracy of both cameras' alignment and quality assurance tests of the x-ray generators and the flat-panel detectors. The traditional linac 6-MV beam characteristics and beam output parameters were also measured. Results revealed a manipulator mechanical mean accuracy of ∼0.1 mm, with individual maximum position uncertainties less than 0.25 mm. The target-locating system mechanical accuracy was found within the acceptance limits. For the most clinically used parameters in the CyberKnife practice, e.g. 100-120 kV and 50-200 ms, kV and exposure time accuracy error were measured as less than 2%, while the precision error of the kV was determined as less than 1%. The acquired images of the ETR grid pattern revealed no geometrical distortion while the critical frequency f values for cameras A and B were calculated as 1.5 lp mm and 1.4 lp mm, respectively. Dose placement measurements were performed in a head and neck phantom. Results revealed sub-millimeter beam delivery precision whereas the total clinical accuracy of the system was measured equal to 0.44 ± 0.12 mm, 0.29 ± 0.10 mm and 0.53 ± 0.16 mm for the skull, fiducial and Xsight spine tracking methods, respectively. The results of this work certify the G4 CyberKnife SRS system capable of delivering high dose distributions with sub-millimeter accuracy and precision to intracranial and extracranial lesions. Moreover, total clinical accuracy of the investigated G4 system was found to be improved for the skull and fiducial tracking methods and was comparable for Xsight spine tracking method compared with the earlier generation of the instrument. © 2008 Institute of Physics and Engineering in Medicine.

Provide Feedback

Have ideas for a new metric? Would you like to see something else here?Let us know