Accurate position estimation methods based on electrical impedance tomography measurements
Measurement Science and Technology, ISSN: 1361-6501, Vol: 28, Issue: 8
2017
- 3Citations
- 8Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
Electrical impedance tomography (EIT) is a technology that estimates the electrical properties of a body or a cross section. Its main advantages are its non-invasiveness, low cost and operation free of radiation. The estimation of the conductivity field leads to low resolution images compared with other technologies, and high computational cost. However, in many applications the target information lies in a low intrinsic dimensionality of the conductivity field. The estimation of this low-dimensional information is addressed in this work. It proposes optimization-based and data-driven approaches for estimating this low-dimensional information. The accuracy of the results obtained with these approaches depends on modelling and experimental conditions. Optimization approaches are sensitive to model discretization, type of cost function and searching algorithms. Data-driven methods are sensitive to the assumed model structure and the data set used for parameter estimation. The system configuration and experimental conditions, such as number of electrodes and signal-to-noise ratio (SNR), also have an impact on the results. In order to illustrate the effects of all these factors, the position estimation of a circular anomaly is addressed. Optimization methods based on weighted error cost functions and derivate-free optimization algorithms provided the best results. Data-driven approaches based on linear models provided, in this case, good estimates, but the use of nonlinear models enhanced the estimation accuracy. The results obtained by optimization-based algorithms were less sensitive to experimental conditions, such as number of electrodes and SNR, than data-driven approaches. Position estimation mean squared errors for simulation and experimental conditions were more than twice for the optimization-based approaches compared with the data-driven ones. The experimental position estimation mean squared error of the data-driven models using a 16-electrode setup was less than 0.05% of the tomograph radius value. These results demonstrate that the proposed approaches can estimate an object's position accurately based on EIT measurements if enough process information is available for training or modelling. Since they do not require complex calculations it is possible to use them in real-time applications without requiring high-performance computers.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85025436315&origin=inward; http://dx.doi.org/10.1088/1361-6501/aa743f; https://iopscience.iop.org/article/10.1088/1361-6501/aa743f; http://iopscience.iop.org/article/10.1088/1361-6501/aa743f/pdf; http://stacks.iop.org/0957-0233/28/i=8/a=084003/pdf; http://stacks.iop.org/0957-0233/28/i=8/a=084003?key=crossref.07422a5b11daea04f1936f94c2b028f1; http://iopscience.iop.org/article/10.1088/1361-6501/aa743f; https://dx.doi.org/10.1088/1361-6501/aa743f; https://validate.perfdrive.com/fb803c746e9148689b3984a31fccd902/?ssa=728c1ae5-159b-46b2-9664-5448a6caf198&ssb=41251246228&ssc=https%3A%2F%2Fiopscience.iop.org%2Farticle%2F10.1088%2F1361-6501%2Faa743f&ssi=17d98b44-8427-45e5-b956-913b9c5a1b7d&ssk=support@shieldsquare.com&ssm=0106967635989233472223038824900763&ssn=1bad414baf8260a16a2596d6600ebdcb135ae7e44089-5b4c-4bba-99401b&sso=45b7880e-62ddb6055d962560c7f1ca3e61a8a85ee8ee291fcc0d300c&ssp=27898026441722189553172229854776841&ssq=19498773600543907052196580509269901610433&ssr=NTIuMy4yMTcuMjU0&sst=com.plumanalytics&ssu=&ssv=&ssw=&ssx=eyJyZCI6ImlvcC5vcmciLCJfX3V6bWYiOiI3ZjYwMDA3NmNmYmIwZC1hOTY5LTQwMjItYWM3My04NjU0NDg0NTczMTgxNzIyMTk2NTgwNDk0Mzk0MjQ4MDktMzE0NmZiY2MyMTUzOTQzMzcyMjIiLCJ1em14IjoiN2Y5MDAwNWZlYjYxNzctOTJlZC00ZjU2LThmZTEtNTk5ZDljOTJjNDE1Mi0xNzIyMTk2NTgwNDk0Mzk0MjQ4MDktZDRkNGRlYmI1NTc3YmMyODcyMjIifQ==
IOP Publishing
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know