Evaluation of a modular all-in-one high-resolution PET detector and readout electronics setup
Physics in Medicine and Biology, ISSN: 1361-6560, Vol: 68, Issue: 11
2023
- 2Citations
- 7Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations2
- Citation Indexes2
- Captures7
- Readers7
Article Description
Objective. The all-in-one solution and modularity of the C13500 series TOF-PET detector modules (Hamamatsu Photonics K.K., Hamamatsu, Japan) make them a highly attractive candidate for the development of positron emission tomography (PET) systems. However, the commercially available portfolio targets clinical whole-body PET systems with a scintillation crystal cross area of 3.1 × 3.1 mm. To extend the modules for high resolution (preclinical or organ specific) systems, the support for smaller scintillation crystals is required. Approach. In this work, a PET detector was developed based on the TOF-PET modules using a light sharing approach, 16 × 16 lutetium oxyorthosilicate (LSO) scintillation crystals with a size of 1.51 × 1.51 × 10.00 mm readout with 8 × 8 photosensor channels of size 3.0 × 3.0 mm. In addition to hardware and software development, the optimized parameter settings for the adapted configuration were evaluated. Main Results. A factor of two in amplification of the analog signal compared to the minimum gain setting was necessary for an accurate crystal identification (peak-to-valley ratio 14.9 ± 5.9). A further increase to a factor of three was not determined as optimum as the time over threshold duration, thus pile-up probability, increased from 1032.1 ± 109.5 to 1789.5 ± 218.5 ns (photopeak position). With this amplification a full width at half maximum (FWHM) energy resolution of 14.1 ± 2.0% and a high linearity of the energy detection was obtained. A FWHM coincidence resolving time (CRT) of 313 ps was achieved by using a low timing threshold, increasing the bandwidth of the front-end circuit and using a narrow ± 1σ energy window. To approximately double the sensitivity and reduce the power consumption, the timing parameters were adjusted resulting in a FWHM CRT of 354 ps (±2σ). Significance. Based on the results obtained with the proof-of-concept detector setup, we confirm the modularity and flexibility of the all-in-one TOF-PET detector modules for the future development of application-specific high-resolution PET systems.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85160780103&origin=inward; http://dx.doi.org/10.1088/1361-6560/acd432; http://www.ncbi.nlm.nih.gov/pubmed/37164021; https://iopscience.iop.org/article/10.1088/1361-6560/acd432; https://dx.doi.org/10.1088/1361-6560/acd432; https://validate.perfdrive.com/9730847aceed30627ebd520e46ee70b2/?ssa=21edf515-15ce-4b01-90c6-d084d23453a4&ssb=54724281518&ssc=https%3A%2F%2Fiopscience.iop.org%2Farticle%2F10.1088%2F1361-6560%2Facd432&ssi=4dc7b116-cnvj-4296-89b1-4b89de84eed6&ssk=botmanager_support@radware.com&ssm=72849416785383610268848184486886009&ssn=e998acc2b8e2c437eda7d0d64f6e1e7e9e62e6de3031-b8c3-4fbb-aca19a&sso=067b4cc8-339afdbf16e26db626be2a35ef29436313e081881a6ccb60&ssp=18565990241738450792173879621556417&ssq=63312956363467489154608198109193680006462&ssr=NTIuMy4yMTcuMjU0&sst=com.plumanalytics&ssu=&ssv=&ssw=&ssx=eyJfX3V6bWYiOiI3ZjYwMDBlNDViMGUyMS0yNzYwLTRlMGYtOGM5My04OTJlMDRhODAyOWYxNzM4NDA4MTk4NTU1MzU1NDM2MDE0LTFlYzNiNmRjMDg5MjRlZDIyNjg4NCIsInV6bXgiOiI3ZjkwMDA3NGVkZTk5OC00MTBhLTRlNTctYjZkYi00ODhiMmI0NjhlYzM1LTE3Mzg0MDgxOTg1NTUzNTU0MzYwMTQtYWE3NDg1ZTJlYWFlODRlZDI2ODg0IiwicmQiOiJpb3Aub3JnIn0=
IOP Publishing
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know