Determination of resistance at zero and infinite frequencies in bioimpedance spectroscopy for assessment of body composition in babies
Physiological Measurement, ISSN: 1361-6579, Vol: 45, Issue: 5
2024
- 1Citations
- 7Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
Objective. Bioimpedance spectroscopy (BIS) is a popular technique for the assessment of body composition in children and adults but has not found extensive use in babies and infants. This due primarily to technical difficulties of measurement in these groups. Although improvements in data modelling have, in part, mitigated this issue, the problem continues to yield unacceptably high rates of poor quality data. This study investigated an alternative data modelling procedure obviating issues associated with BIS measurements in babies and infants. Approach. BIS data are conventionally analysed according to the Cole model describing the impedance response of body tissues to an applied AC current. This approach is susceptible to errors due to capacitive leakage errors of measurement at high frequency. The alternative is to model BIS data based on the resistance-frequency spectrum rather than the reactance-resistance Cole model thereby avoiding capacitive error impacts upon reactance measurements. Main results. The resistance-frequency approach allowed analysis of 100% of data files obtained from BIS measurements in 72 babies compared to 87% successful analyses with the Cole model. Resistance-frequency modelling error (percentage standard error of the estimate) was half that of the Cole method. Estimated resistances at zero and infinite frequency were used to predict body composition. Resistance-based prediction of fat-free mass (FFM) exhibited a 30% improvement in the two-standard deviation limits of agreement with reference FFM measured by air displacement plethysmography when compared to Cole model-based predictions. Significance. This study has demonstrated improvement in the analysis of BIS data based on the resistance frequency response rather than conventional Cole modelling. This approach is recommended for use where BIS data are compromised by high frequency capacitive leakage errors such as those obtained in babies and infants.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85192400221&origin=inward; http://dx.doi.org/10.1088/1361-6579/ad3dc0; http://www.ncbi.nlm.nih.gov/pubmed/38604189; https://iopscience.iop.org/article/10.1088/1361-6579/ad3dc0; https://dx.doi.org/10.1088/1361-6579/ad3dc0; https://validate.perfdrive.com/9730847aceed30627ebd520e46ee70b2/?ssa=6bb57c76-3ae7-42c1-b6f0-2b94242a2dc9&ssb=32394260402&ssc=https%3A%2F%2Fiopscience.iop.org%2Farticle%2F10.1088%2F1361-6579%2Fad3dc0&ssi=868c6580-cnvj-4652-b9cd-1f491c6f7d2c&ssk=botmanager_support@radware.com&ssm=18985081841275204459163663419552367&ssn=960f17980033742288b6912041d343cd598c9257b256-2e92-4da1-a57957&sso=e22c1013-e6f1be2ceeb8938fc460290c758e0152aed3b9ba1027953f&ssp=63514412561731227483173168146841051&ssq=44717332460629456151275300920280284797653&ssr=NTIuMy4yMTcuMjU0&sst=com.plumanalytics&ssu=&ssv=&ssw=&ssx=eyJyZCI6ImlvcC5vcmciLCJfX3V6bWYiOiI3ZjYwMDA4YzlmMGU3NC00YmYzLTRiZWMtYjRiOC03ZDI5MGJiODNkZTUxNzMxMjc1MzAwNDc1MzQ5MzA2NDg4LTM3ZDA1MTk0MzJlYTU1NTE0NTkxNiIsInV6bXgiOiI3ZjkwMDA5YzczNWZhZS0wNThiLTQxNDktYTEzYi1kMzE2NjhlMzRkYWU1LTE3MzEyNzUzMDA0NzUzNDkzMDY0ODgtMThhYTIyZGQ3NjUzYWM1NTQ1OTE2In0=
IOP Publishing
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know