An assessment of the ageing of the absolute spectral responsivity of trap detectors at krypton ion laser emission wavelengths
Metrologia, ISSN: 1681-7575, Vol: 61, Issue: 5
2024
- 1Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Captures1
- Readers1
Article Description
We have assessed the absolute spectral responsivities of three-element trap detectors calibrated against the National Physical Laboratory primary standard cryogenic radiometer at eight krypton ion laser emission wavelengths over an approximate period of 20 years. As expected, we observed that the absolute spectral responsivities decrease with time. Additionally, we found that as the wavelength decreases, the ageing rate increases. At 356.4 nm, an average responsivity decrease of around −1800 ppm yr is reported. While at longer wavelengths, the slowest rate of ageing, approximately −40 ppm yr, occurs at 799.3 nm. Interestingly, the year-on-year changes exhibit a relatively linear trend, allowing us to predict the future performance of the trap detectors. It is important to note, however, that predicted performance cannot be guaranteed and regular recalibration against a primary standard is essential, especially if low calibration uncertainties are required.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85199688260&origin=inward; http://dx.doi.org/10.1088/1681-7575/ad615d; https://iopscience.iop.org/article/10.1088/1681-7575/ad615d; https://dx.doi.org/10.1088/1681-7575/ad615d; https://validate.perfdrive.com/fb803c746e9148689b3984a31fccd902/?ssa=de2b085e-3ed6-4f9b-b0fe-5dc599372212&ssb=87518217853&ssc=https%3A%2F%2Fiopscience.iop.org%2Farticle%2F10.1088%2F1681-7575%2Fad615d&ssi=9f01155b-8427-44d1-9cc4-0606beb6ca40&ssk=support@shieldsquare.com&ssm=884293623631632646108356934176535&ssn=5421ab678df535af3e2fc7112beb0bb3d7ec1d717baf-41c9-4be8-b4d55d&sso=9ee802e5-8edfa45a35345f307842e5bbbdb9671fc3779c859694eaf5&ssp=91362099151722477588172242959899179&ssq=61635086418995683395149886331061496019499&ssr=NTIuMy4yMTcuMjU0&sst=com.plumanalytics&ssu=&ssv=&ssw=&ssx=eyJyZCI6ImlvcC5vcmciLCJfX3V6bWYiOiI3ZjYwMDBhYzc1Mjc3MS00NDY5LTQ1YzEtYjIyZC01ZTMxN2I4YmJmMzUxNzIyNDQ5ODg2MzE1MTQzMDMzMzAtZGEzMTNhZmM5Nzc1ZjZmMzYxMCIsInV6bXgiOiI3ZjkwMDA2MGFiMzgwNC0yODIyLTQ4MTYtOWM4ZC0wMzZlOGNjM2U5MzIxLTE3MjI0NDk4ODYzMTUxNDMwMzMzMC05YWU5NzkzY2VlMGIyNzQ1NjEwIn0=
IOP Publishing
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know