Study on real-time detection method for electron beam selective melting process
Journal of Physics: Conference Series, ISSN: 1742-6596, Vol: 1676, Issue: 1
2020
- 1Citations
- 2Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Conference Paper Description
In order to solve the problem of lack of effective and real-time monitoring evaluation method for electron beam selective melting (EBSM) processing, a technique of acquiring real-time secondary electron (SE) imaging through layer-by-layer scanning is presented, which could monitor the defects of components. Basic design scheme, including the Electron beam scanning system, signal processing and imaging system, is introduced in this paper. Capability of generating digital image and choosing different monitoring area for the real-time monitoring system has been verified by series of experiments. Results suggest that the maximum resolution of the prototype has reached 0.3mm.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85097053193&origin=inward; http://dx.doi.org/10.1088/1742-6596/1676/1/012196; https://iopscience.iop.org/article/10.1088/1742-6596/1676/1/012196; https://dx.doi.org/10.1088/1742-6596/1676/1/012196; https://validate.perfdrive.com/9730847aceed30627ebd520e46ee70b2/?ssa=43fc71cc-f015-49fe-8f33-91a79fc791e5&ssb=18815263142&ssc=https%3A%2F%2Fiopscience.iop.org%2Farticle%2F10.1088%2F1742-6596%2F1676%2F1%2F012196&ssi=2b690881-cnvj-4413-af22-72afe88f9c17&ssk=botmanager_support@radware.com&ssm=35606057965605450239838953287551516&ssn=2a8ef699371ad389e1738edcfe3af43f9f5c2617fe85-f716-4004-bfba4a&sso=f13563eb-7b570d50c5e366d9b642b93f033977ffe7e5d584f813526e&ssp=30741026561726010077172621857209822&ssq=14359684695877833100577985431326297937796&ssr=NTIuMy4yMTcuMjU0&sst=com.plumanalytics&ssu=&ssv=&ssw=&ssx=eyJ1em14IjoiN2Y5MDAwYzFkZTEzNzktNTg3Yi00ZmNlLTgyOTMtNjUwMDdhZTEwM2E1My0xNzI2MDc3OTg1NDI3MTY4OTczNTU3LTM5YjUyYzEzMTcxZmViMmEyMzk4MCIsInJkIjoiaW9wLm9yZyIsIl9fdXptZiI6IjdmNjAwMDZjMTgzZGM2LWE5ZDAtNDM3NS05N2FlLTljNmQxMGYxMzQwMDE3MjYwNzc5ODU0MjcxNjg5NzM1NTctMGY3NzdhNjE0OWRiOWYxNTIzOTgzIn0=
IOP Publishing
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know