Electric field measurement using a non-perturbative method based on a calibrated electric potential sensor
Journal of Physics: Conference Series, ISSN: 1742-6596, Vol: 301, Issue: 1
2011
- 4Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Captures4
- Readers4
Conference Paper Description
We present results of finite element analysis for simple test structures which demonstrate clearly that the measurement situation is complex. The test structure consists of an open geometry parallel plate capacitor within a screened enclosure. Indeed, the presence of earthed objects, even at considerable distances, is shown to have a significant effect on the field geometry close to the source. These simulations are compared with field measurements made using an ultra-high input impedance sensor, the Electric Potential Sensor. A single experimentally determined calibration factor is all that is required to achieve excellent agreement between experimental measurements and the results of the simulations. Given this, the sensor is capable of mapping accurately, and in a non-perturbative manner, the spatial potential both within and outside of the test structure.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=80051677795&origin=inward; http://dx.doi.org/10.1088/1742-6596/301/1/012046; https://iopscience.iop.org/article/10.1088/1742-6596/301/1/012046; http://stacks.iop.org/1742-6596/301/i=1/a=012046/pdf; https://dx.doi.org/10.1088/1742-6596/301/1/012046; https://validate.perfdrive.com/9730847aceed30627ebd520e46ee70b2/?ssa=7148bc30-73bd-41ed-b8b8-2eb4ffd8074a&ssb=47534245666&ssc=https%3A%2F%2Fiopscience.iop.org%2Farticle%2F10.1088%2F1742-6596%2F301%2F1%2F012046&ssi=18f90355-cnvj-4a12-b75f-88bbdcdeb637&ssk=botmanager_support@radware.com&ssm=064778765824814236982998378431752600&ssn=5cf7190beaf877beead63bcd1d1bac47248f0900c3c4-8990-4f21-ac6dc5&sso=4fee9f8c-bc564dd29dea45e0cc35ea7a2d5013cfefea099cd3cc7be5&ssp=36499149171726524095172702731295611&ssq=83639102102551060952429239482048207542253&ssr=NTIuMy4yMTcuMjU0&sst=com.plumanalytics&ssu=&ssv=&ssw=&ssx=eyJ1em14IjoiN2Y5MDAwMGMxZDc2YmItMzk2MS00N2VjLTlkZGItNjdmYTVhZTY2ODdlNy0xNzI2NTI5MjM5NDUzNDkxNzg2NDc3LWY5ZGFlNzczZmQ1NDUxYWY2OTgwNTkiLCJyZCI6ImlvcC5vcmciLCJfX3V6bWYiOiI3ZjYwMDBkNzYzNGE3Ni05ZTRkLTRjMmMtYjJhMC1mYzAzNGMyZjE1MjkxNzI2NTI5MjM5NDUzNDkxNzg2NDc3LWMyNDUzNWIzM2NhODUyNTk2OTgxMzcifQ==
IOP Publishing
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know