Design and construction of the MicroBooNE detector
Journal of Instrumentation, ISSN: 1748-0221, Vol: 12, Issue: 2, Page: P02017-P02017
2017
- 55Citations
- 72Captures
- 2Mentions
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations55
- Citation Indexes55
- CrossRef55
- Captures72
- Readers72
- 72
- Mentions2
- References2
- Wikipedia2
Article Description
This paper describes the design and construction of the MicroBooNE liquid argon time projection chamber and associated systems. MicroBooNE is the first phase of the Short Baseline Neutrino program, located at Fermilab, and will utilize the capabilities of liquid argon detectors to examine a rich assortment of physics topics. In this document details of design specifications, assembly procedures, and acceptance tests are reported.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85033371369&origin=inward; http://dx.doi.org/10.1088/1748-0221/12/02/p02017; http://stacks.iop.org/1748-0221/12/i=02/a=P02017?key=crossref.6b1f60db0fcc2876b4b33acc0b8485a4; http://stacks.iop.org/1748-0221/12/i=02/a=P02017/pdf; https://iopscience.iop.org/article/10.1088/1748-0221/12/02/P02017; https://dx.doi.org/10.1088/1748-0221/12/02/p02017; https://validate.perfdrive.com/9730847aceed30627ebd520e46ee70b2/?ssa=484168a0-f1be-44e7-8f69-cd3d0d64a8be&ssb=18038244769&ssc=https%3A%2F%2Fiopscience.iop.org%2Farticle%2F10.1088%2F1748-0221%2F12%2F02%2FP02017&ssi=1680c8a7-cnvj-48ec-b520-667411886612&ssk=botmanager_support@radware.com&ssm=476051191210416168109672004763065143&ssn=aeabb4847bfccc07a933d2a951fcaedc24d90900c3c4-8990-4f21-acb841&sso=9c959f8c-bc564dd29deaf7b82f8868ecd883cb5a30607f98aba0eca3&ssp=87771706191726554809172704528175530&ssq=17309499961697789356329239003907852849942&ssr=NTIuMy4yMTcuMjU0&sst=com.plumanalytics&ssu=&ssv=&ssw=&ssx=eyJfX3V6bWYiOiI3ZjYwMDBkNzYzNGE3Ni05ZTRkLTRjMmMtYjJhMC1mYzAzNGMyZjE1MjkxNzI2NTI5MjM5NDUzNTcwMzc2ODkwLTQzZTMzOTUwMGY2YWIxMmU4MTA3ODciLCJyZCI6ImlvcC5vcmciLCJ1em14IjoiN2Y5MDAwMGMxZDc2YmItMzk2MS00N2VjLTlkZGItNjdmYTVhZTY2ODdlOC0xNzI2NTI5MjM5NDUzNTcwMzc2ODkwLTkyMzc5MjRkMGFmZTlkNjg4MTA3MDAifQ==
IOP Publishing
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know