Digital holographic interferometry method for tracking detector modules displacement
Journal of Instrumentation, ISSN: 1748-0221, Vol: 18, Issue: 11
2023
- 2Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Captures2
- Readers2
Article Description
In high energy particle physics scattering experiments, the precision of the reconstructed particle tracks can be fundamental. For this reason, a method for detecting the displacement of tracking detector modules is developed. The modules are silicon planes mounted on a frame and used in the MUonE project, which aims at a precision measurement of the scattering angle of elastic muon-electron scattering. From the scattering angle, the hadronic contribution to the anomalous magnetic moment of the muon is extracted. To achieve the desired accuracy, the position of the tracking detector planes must be monitored. The allowable relative displacements must be less than 10 μ m. To meet the specifications and to monitor as large an area of the detector as possible, a digital holographic interferometer was developed. It is based on a novel lens-less design in off-axis holographic geometry. Light from a fiber-coupled laser source is split by a fiber beam splitter, with one output used to illuminate the detector plane and the other for the reference beam. The two beams produce an interference pattern on a CMOS image sensor. To obtain relative displacement information, successive images are superimposed on an initial reference image and reconstructed by solving the Rayleigh-Sommerfeld diffraction integral taking into account the spherical wavefronts of the beams. The interference fringes that appear in the reconstructed holographic image provide a measure of the relative displacement of the detector plane compared to the initial position. The performance of the reconstruction method used was verified with the proposed setup at a real tracking station.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85179761113&origin=inward; http://dx.doi.org/10.1088/1748-0221/18/11/c11030; https://iopscience.iop.org/article/10.1088/1748-0221/18/11/C11030; https://dx.doi.org/10.1088/1748-0221/18/11/c11030; https://validate.perfdrive.com/9730847aceed30627ebd520e46ee70b2/?ssa=e2ea55cb-03d9-425f-a198-4830a81b728e&ssb=09193254302&ssc=https%3A%2F%2Fiopscience.iop.org%2Farticle%2F10.1088%2F1748-0221%2F18%2F11%2FC11030&ssi=7d917196-cnvj-4d9c-995e-bbc245322e91&ssk=botmanager_support@radware.com&ssm=729237355809758049064995649605522357&ssn=fe67c74c5095db9b372c1c9339e1690d64d50900c3c4-8990-4f21-a56da8&sso=9d0fbf8c-bc564dd29dea1485452508cbc908b13668a83c118e6b7857&ssp=86782606561726551405172711043599211&ssq=11378864499715156821129239793299655788562&ssr=NTIuMy4yMTcuMjU0&sst=com.plumanalytics&ssu=&ssv=&ssw=&ssx=eyJ1em14IjoiN2Y5MDAwMGMxZDc2YmItMzk2MS00N2VjLTlkZGItNjdmYTVhZTY2ODdlOS0xNzI2NTI5MjM5NDUzNjE1NzU4NDkyLTEzOTk2MmVlMjNiYjUyMzI5MDYxOTYiLCJfX3V6bWYiOiI3ZjYwMDBkNzYzNGE3Ni05ZTRkLTRjMmMtYjJhMC1mYzAzNGMyZjE1MjkxNzI2NTI5MjM5NDUzNjE1NzU4NDkyLTZjMmE0NWU0YmI1OTJiOTY5MDYyOTIiLCJyZCI6ImlvcC5vcmcifQ==