Electrodecolorization of remazol violet with graphite electrodes : Application of Statistical Designs and Regression Analysis
IOP Conference Series: Materials Science and Engineering, ISSN: 1757-899X, Vol: 620, Issue: 1
2019
- 6Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Captures6
- Readers6
Conference Paper Description
The electrodecolorization process of the remazol violet (RV) dye using graphite as an electrode has been done well. The RV is one of the synthetic dyes that are often used in the textile, paper, and other coloring industries. The parameters used in this study were RV concentration (20 mg/L-100 mg/L), pH (2-10), electrodecolorization time (2 minutes-20 minutes), volume HO (0 mL-12 mL) and voltage (2 V-12 V). Based on experiments of 20 data that have been investigated then made the design of statistical model. The application of statistical design and regression analysis in this research is tested the feasibility, then tested by building data based on experimental data as amount 87319 data. This design is supported by ANOVA test, RMSE value, and ADD as the strengthening of the resulting model. Based on this study, the optimum conditions for pH parameters, electrodecolorization process time, H2O2 volume, RV concentration and voltage are 4;10 minutes;10 mL;20 mg/L; and 2V with a percentage of decolorization of 83.50%. The p-value results of the ANOVA test, the RMSE value, and ADD sequentially from this study are 0.002; 0,000; 0.201 so that the resulting model can be recommended for the application in dye waste management.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85075984352&origin=inward; http://dx.doi.org/10.1088/1757-899x/620/1/012016; https://iopscience.iop.org/article/10.1088/1757-899X/620/1/012016; https://iopscience.iop.org/article/10.1088/1757-899X/620/1/012016/pdf; https://dx.doi.org/10.1088/1757-899x/620/1/012016; https://validate.perfdrive.com/9730847aceed30627ebd520e46ee70b2/?ssa=52d7a9ac-570f-490b-be8a-2a1b487040bf&ssb=17779214145&ssc=https%3A%2F%2Fiopscience.iop.org%2Farticle%2F10.1088%2F1757-899X%2F620%2F1%2F012016&ssi=ea3d4ef9-cnvj-4e19-8a49-8c2e9703bdac&ssk=botmanager_support@radware.com&ssm=96216091970371376163692948278062844&ssn=4061f5b66521144a107cfb8c2191ed8165b69257b256-2e92-4da1-af8ef3&sso=e8cff013-e6f1be2ceeb8c9c280c0bcd0714cb28b85aced6ec9e476df&ssp=62074098221731241871173137209916768&ssq=73618159743631994785975300561654588039758&ssr=NTIuMy4yMTcuMjU0&sst=com.plumanalytics&ssu=&ssv=&ssw=&ssx=eyJfX3V6bWYiOiI3ZjYwMDA4YzlmMGU3NC00YmYzLTRiZWMtYjRiOC03ZDI5MGJiODNkZTUxNzMxMjc1MzAwNDc1MTIyMTM2NDc1LTg5MWY3MGY1NzdhMzk1MmYxNjM2OSIsInV6bXgiOiI3ZjkwMDA5YzczNWZhZS0wNThiLTQxNDktYTEzYi1kMzE2NjhlMzRkYWUzLTE3MzEyNzUzMDA0NzUxMjIxMzY0NzUtYzM4NjZjMTExMjJmYjJiYzE2MzY5IiwicmQiOiJpb3Aub3JnIn0=
IOP Publishing
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know