Effect of tracheal tube cuff shape on fluid leakage across the cuff: an in vitro study
British Journal of Anaesthesia, ISSN: 0007-0912, Vol: 105, Issue: 4, Page: 538-543
2010
- 75Citations
- 59Captures
- 1Mentions
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations75
- Citation Indexes75
- 75
- CrossRef64
- Captures59
- Readers59
- 59
- Mentions1
- News Mentions1
- News1
Most Recent News
Taper-shaped Cuff Endotracheal Tube Against Respiratory Infections; TETRIS
STUDY INFORMATION OFFICIAL TITLE: Effect of Endotracheal Tube With Taper-shaped Cuff on Incidence of Postoperative Pneumonia After Aortic Surgery CURRENT STATUS: Completed STUDY TYPE: Interventional
Article Description
This study compared the fluid leakage in the new ‘tapered’ shaped against the classic ‘cylindrical’ shaped tracheal tube cuffs when placed in different sized tracheas. The 7.5 mm internal diameter (ID) tracheal tube cuffs—Tapered Seal Guard (TSG), Standard Seal Guard (SSG), Hi-Lo, Microcuff, Ruesch, and Portex Profile—were compared in an in vitro apparatus. Vertical artificial tracheas with 16, 20, and 22 mm ID were intubated, 5 ml clear water was applied above the unlubricated tube cuffs, and fluid leakage was measured up to 60 min. Data of tapered vs non-tapered tube cuffs (16 observations) were compared for each tracheal diameter using the Mann–Whitney test. Median (range) fluid leakage (ml) at 60 min was 2.14 (0.05–4.88), 1.14 (0.00–4.84), and 0.13 (0.00–1.32), respectively, for 16, 20, and 22 mm tracheas in the TSG tube studies when compared with 4.58 (0.44–4.88), 2.21 (0.00–4.81), and 0.00 (0.00–4.81) in the SSG tube and 4.54 (1.54–4.82), 0.90 (0.00–4.49), and 4.85 (4.40–4.99) in the Microcuff tube studies. Leakage in all polyvinylchloride (PVC) tube cuffs was almost complete (5 ml) within 5 min ( P <0.001). The tapered PU tube cuff was as effective as the cylindrical PU cuffs in smaller tracheal diameters and was more efficient than the cylindrical Microcuff PU tube cuff in larger tracheal diameter in preventing subglottic fluid leakage across the tube cuff tested in this in vitro study. PVC tube cuffs leaked much more and faster than PU cuffs.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S0007091217334840; http://dx.doi.org/10.1093/bja/aeq202; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=77956941426&origin=inward; http://www.ncbi.nlm.nih.gov/pubmed/20682571; https://linkinghub.elsevier.com/retrieve/pii/S0007091217334840; https://dx.doi.org/10.1093/bja/aeq202