Vascular pressure bands on high-resolution esophageal manometry with impedance studies
Diseases of the Esophagus, ISSN: 1442-2050, Vol: 33, Issue: 3
2020
- 3Citations
- 5Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
Horizontal pressure bands on high-resolution esophageal manometry with impedance (HREMI) tracings are often seen and thought to be due to cardiovascular structures compressing the esophagus. The aim of this study was to determine the prevalence and location of vascular pressure bands on HREMI studies and correlate these pressure bands to bolus clearance. HREMI studies in supine and upright positions from patients and normal volunteers were reviewed. Pressure bands were defined as bands of horizontal pressure greater than the 20 mmHg isobaric contour. Each swallow was reviewed with impedance to determine if bolus transit was impaired by the band. 38.6% of 251 patients and 36.4% of 11 normal controls had a pressure band present. There were a greater number of bands in supine versus upright position (patients: 130 vs. 25, P < 0.001 and controls: 6 vs. 1). Patients with pressure bands had similar demographics (age, gender, BMI) compared to those without. Average distal contractile integral of bands was greater in supine compared to upright (133 ± 201 vs. 60 ± 148 mmHg cm s, P < 0.05). Bands were commonly located clustered at 46 and 72% of esophageal length. Bolus transit was impaired by bands in 20.4% of supine and 14.0% of upright swallows. Vascular pressure bands can have a prominent appearance on HREMI studies, present in, being more prevalent and having greater pressure in the supine than the upright position. These vascular bands, when present, may impair esophageal transit.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85081945917&origin=inward; http://dx.doi.org/10.1093/dote/doz093; http://www.ncbi.nlm.nih.gov/pubmed/31825486; https://academic.oup.com/dote/article/doi/10.1093/dote/doz093/5673266; https://dx.doi.org/10.1093/dote/doz093; https://academic.oup.com/dote/article/33/3/doz093/5673266
Oxford University Press (OUP)
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know