Comparison of body fluid distribution between chronic haemodialysis and peritoneal dialysis patients as assessed by biophysical and biochemical methods
Nephrology Dialysis Transplantation, ISSN: 0931-0509, Vol: 16, Issue: 12, Page: 2378-2385
2001
- 116Citations
- 24Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations116
- Citation Indexes116
- 116
- CrossRef83
- Captures24
- Readers24
- 24
Article Description
Background. The control of extracellular volume is a key parameter for reducing hypertension and the incidence of cardiovascular mortality in dialysis patients. In recent years bioimpedance measurement (BIA) has been proven as a non-invasive and accurate method for measuring intracellular and extracellular fluid spaces in man. In addition, plasma atrial natriuretic peptide (ANP) and cyclic guanosine monophosphatase (cGMP) concentrations have been shown to reflect central venous filling. Using these methods, we compared body fluid status between stable patients on haemodialysis and peritoneal dialysis. Methods. Thirty-nine chronic haemodialysis patients, 43 chronic peritoneal dialysis patients and 22 healthy controls were included in the study. Multifrequency BIA was performed using the Xitron BIS4000B device (frequencies from 5 to 500 kHz were scanned and fitted) in patients before and after haemodialysis. Peritoneal dialysis patients were measured after drainage of the dialysate. Plasma ANP and cGMP levels were measured in plasma using a I solid phase RIA. Serum albumin concentrations and serum osmolality were measured in all patients. The body fluid data were analysed in relation with the clinical findings. Results. Total body water (TBW) was 0.471 ± 0.066 1/kg before haemodialysis and 0.466 ± 0.054 1/kg after haemodialysis. Peritoneal dialysis patients had a TBW (0.498 ± 0.063 1/kg) that was greater than the before and after dialysis values of haemodialysis patients. The extracellular body fluid (V) was increased pre-haemodialysis. It was even greater in peritoneal dialysis patients compared with patients both pre- and post-haemodialysis (pre 0.276 ± 0.037 1/kg; post 0.254 ± 0.034 1/kg; peritoneal dialysis 0.293 ± 0.042 1/kg, P < 0.05). However, plasma ANP concentrations (representing intravascular filling) in peritoneal dialysis patients were comparable with post-haemodialysis values (284 ± 191 pg/ml vs 286 ± 144 pg/ml). The correlation coefficient between sysRR and V was r = 0.257 in haemodialysis (P = 0.057) and r = 0.258 in peritoneal dialysis (P < 0.05). A significant negative correlation was found between serum albumin and V/TBW in peritoneal dialysis patients (r = -0.624). Conclusion. Body fluid analysis by BIA demonstrated that TBW and V were increased in peritoneal dialysis patients, and were comparable or even greater than values found before haemodialysis. However, plasma ANP levels indicated that intravascular filling was not increased in peritoneal dialysis. The ratio of V to TBW was correlated to systolic pressure and negatively to serum albumin in peritoneal dialysis patients.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=0035206609&origin=inward; http://dx.doi.org/10.1093/ndt/16.12.2378; http://www.ncbi.nlm.nih.gov/pubmed/11733630; http://academic.oup.com/ndt/article/16/12/2378/1816731; https://dx.doi.org/10.1093/ndt/16.12.2378; https://academic.oup.com/ndt/article-abstract/16/12/2378/1816731?redirectedFrom=fulltext