A radiation exposure index for CT
Radiation Protection Dosimetry, ISSN: 0144-8420, Vol: 157, Issue: 2, Page: 172-180
2013
- 5Citations
- 24Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations5
- Citation Indexes5
- CrossRef3
- Captures24
- Readers24
- 24
Article Description
The purpose of this study is to define an Exposure Index for CT (EI) and to estimate the magnitude of the EI for common clinical CT examinations. For a single-axial rotation of a CT X-ray tube that includes only rays that pass through the patient, the CT Exposure Index (EI) is defined as the average Air Kerma that would be incident on an extended 360 detector array completely surrounding the patient. For an axial scan of a uniform cylindrical phantom, EI can be approximated as T 3 [(CTDI)/4] 3 [β/360] where T is the fractional transmission through the cylinder, CTDI is the CT Dosimetry Index-determined 'free in air' at isocentre, and β/2 is the fan beam angle that will completely irradiate a cylindrical phantom at isocentre. The value of CTDI can be estimated from the weighted CTDI (CTDI) for a given CT examination, and the angle β depends on the irradiation geometry that can be obtained from the cylinder diameter (r) and the focus to isocentre distance (R). At a voltage of 120 kV, transmission through an adult head was ~2.6%, through an adult abdomen~0.4% and through a 5-y-old paediatric abdomen ~3%. Average ratios of CTDI/CTDI were 1.42±0.12 in 16-cm dosimetry phantom and 2.82±0.37 in 32-cm phantom. Values of b ranged from 30.18 (R 5 61 cm and r58 cm) to 85.38 (R 5 55 cm and r520 cm). For an adult head CTexamination, EI was estimated to be~70 μGy at a CTDI of 75 mGy (16 cm), and for an adult abdominal CTexamination, EI was estimated to be~11 μGy at a CTDI of 25 mGy (32 cm). For an abdomen CTexamination in a 5-y-old child, EI was estimated to be ~21 μGy at a CTDI of 20 mGy (16 cm). The EI is introduced that provides a quantitative measure of the amount of the radiation used to generate images in any CTexamination and is analogous to the average image receptor Exposure Index recently proposed for use in projection imaging. The EI metric provides operators with an objective index of the amount of the radiation used to create CT images and can be used to control quantum mottle in CT. © The Author 2013. Published by Oxford University Press. All rights reserved.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84887125594&origin=inward; http://dx.doi.org/10.1093/rpd/nct128; http://www.ncbi.nlm.nih.gov/pubmed/23690648; https://academic.oup.com/rpd/article-lookup/doi/10.1093/rpd/nct128; https://dx.doi.org/10.1093/rpd/nct128; https://academic.oup.com/rpd/article-abstract/157/2/172/1646555?redirectedFrom=fulltext