Biocompatible osteoconductive polymer versus iliac graft: A prospective comparative study for the evaluation of fusion pattern after anterior cervical discectomy
Spine, ISSN: 0362-2436, Vol: 21, Issue: 18, Page: 2123-2130
1996
- 59Citations
- 25Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations59
- Citation Indexes57
- 57
- CrossRef48
- Clinical Citations1
- PubMed Guidelines1
- Policy Citations1
- Policy Citation1
- Captures25
- Readers25
- 24
Article Description
Study Design. One hundred fifteen patients having symptomatic cervical disc disease were recruited prospectively for this study. They were allocated randomly for either autologous iliac bone graft or biocompatible osteoconductive polymer implants. Both groups were compared clinically and radiologically. Objectives. Complications, long-term clinical and radiologic outcome, and hospital stay were compared to determine if biocompatible osteoconductive polymer was an improvement on iliac bone graft in terms of reduced donor site pain and shortened hospital stay. Summary of Background Data. Donor site morbidity is a significant problem in anterior cervical fusion. Hospital stay is another factor in the recent era of cost consciousness. Biocompatible osteoconductive polymer has been used in many centers as a biodegradable implant to circumvent these problems. Methods. Smith-Robinson technique was used in 74 patients, and Cloward technique was used in 41 patients. Sixty-five patients had biocompatible osteoconductive polymer implants, and 50 patients had lilac bone graft. Patients were followed-up routinely in the outpatient clinic where pain visual analogue scale and Odom's criteria were used for outcome evaluation. Plain radiography, computed tomography scan, and magnetic resonance imaging were used for radiologic evaluation. Results. The mean hospital stay was 4.8 days for those with lilac bone graft and 4.7 days for those with biocompatible osteoconductive polymer. Clinical outcome was identical in both groups. The incidence of partial graft protrusion and postoperative intersegmental kyphosis was statistically higher with lilac bone graft (P = 0.018 and P = 0.02, respectively). 'Sclerosis' started to form around biocompatible osteoconductive polymer like a 'halo' at 2 months. It increased with time, and sometimes was associated with new osteophyte formation; however, there was no biocompatible osteoconductive polymer incorporation or biodegradation. Conclusions. Biocompatible osteoconductive polymer acts as a good 'spacer' that reduces graft collapse and intersegmental kyphosis. However, it did not show any radiologic evidence of biodegradation or incorporation during the follow-up period of 24 months.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=0029764813&origin=inward; http://dx.doi.org/10.1097/00007632-199609150-00013; http://www.ncbi.nlm.nih.gov/pubmed/8893437; http://journals.lww.com/00007632-199609150-00013; http://content.wkhealth.com/linkback/openurl?sid=WKPTLP:landingpage&an=00007632-199609150-00013; http://pt.wkhealth.com/pt/re/lwwgateway/landingpage.htm;jsessionid=hKmb5yWzbQSJ9Nv1fBgB8ScPF63Jh8kCjmhGpcJtQGbk3RQz6MGY!1764342379!181195628!8091!-1?sid=WKPTLP:landingpage&an=00007632-199609150-00013