Anesthesiology, ISSN: 1528-1175, Vol: 127, Issue: 4, Page: 614-624
2017
  • 41
    Citations
  • 0
    Usage
  • 134
    Captures
  • 1
    Mentions
  • 0
    Social Media
Metric Options:   Counts1 Year3 Year

Metrics Details

Most Recent News

Should You Get an Epidural? 

Having a baby is an inherently painful proposition. The birth process is punctuated with a series of decisions made around minimizing risks and coping with the pain, which is unpredictable in both intensity and duration. An epidural can help with pain, but how does that change the risks that you and your baby face? Read more...

Article Description

Background: Breastfeeding is an important public health concern. High cumulative doses of epidural fentanyl administered for labor analgesia have been reported to be associated with early termination of breastfeeding. We tested the hypothesis that breastfeeding success is adversely influenced by the cumulative epidural fentanyl dose administered for labor analgesia. Methods: The study was a randomized, double-blind, controlled trial of parous women at greater than 38 weeks gestation who planned to breastfeed, had successfully breastfed a prior infant, and who received neuraxial labor analgesia. Participants were randomized to receive one of three epidural maintenance solutions for labor analgesia (bupivacaine 1 mg/ml, bupivacaine 0.8 mg/ml with fentanyl 1 μg/ml, or bupivacaine 0.625 mg/ml with fentanyl 2 μg/ml). The primary outcome was the proportion of women breastfeeding at 6 weeks postpartum. Maternal and umbilical venous blood fentanyl and bupivacaine concentration at delivery were measured. Results: A total of 345 women were randomized and 305 had complete data for analysis. The frequency of breastfeeding at 6 weeks was 97, 98, and 94% in the groups receiving epidural fentanyl 0, 1, and 2 μg/ml, respectively (P = 0.34). The cumulative fentanyl dose (difference: 37 μg [95% CI of the difference, -58 to 79 μg], P = 0.28) and maternal and umbilical cord venous fentanyl and bupivacaine concentrations did not differ between women who discontinued breastfeeding and those who were still breastfeeding at 6 weeks postpartum. Conclusions: Labor epidural solutions containing fentanyl concentrations as high as 2 μg/ml do not appear to influence breastfeeding rates at 6 weeks postpartum.

Provide Feedback

Have ideas for a new metric? Would you like to see something else here?Let us know