Finite element-based preclinical testing of cemented total hip implants
Clinical Orthopaedics and Related Research, ISSN: 1528-1132, Vol: 456, Page: 138-147
2007
- 38Citations
- 32Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations38
- Citation Indexes38
- 38
- CrossRef29
- Captures32
- Readers32
- 32
Article Description
We developed a finite element model to preclinically test cemented hip implants for damage accumulation, including cement crack formation, creep, and stem migration. Using this model, we simulated the mechanical failure processes of four cemented total hip arthroplasty implants (Lubinus SPII, Mueller Curved, Exeter and Charnley, all with known clinical results) during cyclic normal walking and stair-climbing loads. These four implants were selected to ascertain whether the simulation predicted greater damage development around clinically inferior stems, whether clinically inferior designs could be identified by an initial stress analysis without the prediction of cement damage, and whether the simulation could predict high implant subsidence rates in combination with minimal cement damage. Based on the predicted cement crack patterns and crack formation rates, the simulation correctly identified the clinically inferior implant designs. Based only on the initial stress analysis under a stair-climbing load, it was not possible to identify clinically inferior designs. High subsidence values and minimal cement damage were predicted for the Exeter implant, similar to clinical findings. Our findings suggest the simulation may be effective in differentiating between a range of implants and design features. © 2007 Lippincott Williams & Wilkins, Inc.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=34247473450&origin=inward; http://dx.doi.org/10.1097/blo.0b013e31802ba491; http://www.ncbi.nlm.nih.gov/pubmed/17075379; https://journals.lww.com/00003086-200703000-00025; http://content.wkhealth.com/linkback/openurl?sid=WKPTLP:landingpage&an=00003086-200703000-00025; https://dx.doi.org/10.1097/blo.0b013e31802ba491; https://insights.ovid.com/crossref?an=00003086-200703000-00025