Use of Digital Tomosynthesis in Assessing Accurate Medial Epicondyle Fracture Displacement as Compared with Conventional Radiography and Computed Tomography
Journal of Pediatric Orthopaedics, ISSN: 1539-2570, Vol: 41, Issue: 10, Page: E877-E883
2021
- 3Citations
- 6Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations3
- Citation Indexes3
- CrossRef3
- Captures6
- Readers6
Article Description
Introduction: Medial epicondyle fracture displacement is notoriously difficult to determine on conventional radiography, and follow-up computed tomography (CT) is often obtained to measure precise displacement. Another option for fracture characterization is digital tomosynthesis (DT), a technology providing high in-plane resolution of bony anatomy by acquiring multiple low-dose images in a linear arc. Advantages of DT include lower radiation exposure and lower cost than CT, rapid image acquisition, and a similar patient experience to conventional radiography. The digital application of tomosynthesis is relatively new and is integrated as an add-on feature with modern radiography equipment. This study compares DT, CT and conventional radiography for measurement accuracy in medial epicondyle fractures with the goal of determining relative accuracy in measuring medial epicondyle fracture displacement. Methods: Medial epicondyle fractures were created in 5 cadaveric elbow specimens. Each specimen was imaged with conventional radiography, DT, and CT. True displacement measured by digital calipers was compared with "measured" displacement for each image acquisition. CT images included axial, sagittal, and coronal reformats. DT images of the elbow included anteroposterior (AP) longitudinal and transverse, lateral longitudinal and transverse, and axial longitudinal and transverse. Conventional radiographs included AP, lateral, and axial distal humerus images. Four physicians reviewed all images 3 months later. Each reviewer independently measured maximum apparent fracture displacement to the nearest 0.1 mm. Measurement accuracy was calculated as percent difference [(measured displacement-actual displacement)/actual displacement] for each acquisition. Mean, median, and SD for measurement accuracy were calculated. Two-tailed paired t tests were performed on each acquisition to compare the measurement accuracy. Results: Compared with conventional radiographs, accuracy of DT was superior in AP longitudinal (P=0.03), AP transverse (P=0.01), axial longitudinal (P=0.0001), and axial transverse projections (P=0.001). Accuracy of CT was superior to conventional radiography in the AP projection (P=0.03), but was equivalent in the axial projection (P=0.9). Accuracy of CT was similar to DT in AP longitudinal (P=0.6), AP transverse (P=0.5), and axial longitudinal projections (P=0.07). Accuracy of DT in the axial transverse projection was superior to CT (P=0.03). Conclusion: DT is more accurate than conventional radiography (both AP and axial views) and as accurate as CT in assessing millimeters of displacement of medial epicondyle fracture fragments. Level of Evidence: Level IV - diagnostic study.
Bibliographic Details
Ovid Technologies (Wolters Kluwer Health)
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know