Biomechanical simulation and analysis of scoliosis correction using a fusionless intravertebral epiphyseal device
Spine, ISSN: 1528-1159, Vol: 40, Issue: 6, Page: 369-376
2015
- 17Citations
- 55Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations17
- Citation Indexes17
- 17
- CrossRef14
- Captures55
- Readers55
- 55
Article Description
Study Design. Computer simulations to analyze the biomechanics of a novel compression-based fusionless device (hemistaple) that does not cross the disc for the treatment of adolescent idiopathic scoliosis. Objective. To biomechanically model, simulate, and analyze the hemistaple action using a human finite element model (FEM). Summary of Background Data. A new fusionless growth sparing instrumentation device (hemistaple), which locally compresses the growth plate without spanning the disc, was previously developed and successively tested on different animal models. Methods. Patient-specific FEMs of the spine, rib cage, and pelvis were built using radiographs of 10 scoliotic adolescents (11.7 ± 0.9 yr; Cobb thoracic: 35° ± 7°, lumbar: 24° ± 6°). A validated algorithm allowed simulating the growth (0.8-1.1 mm/yr/vertebra) and growth modulation process (Hueter-Volkmann principle) during a period of 2 years. Four instrumentation configurations on the convex curves were individually simulated (Config 1: 5 thoracic vertebrae with hemistaples on superior endplates; Config 2: same as Config 1 with hemistaples on both endplates; Config 3: same as Config 1 + 4 lumbar vertebrae; Config 4: same as Config 2 + 4 lumbar vertebrae). Results. Without hemistaples, on average the thoracic and lumbar Cobb angles, respectively, progressed from 35° to 56° and 24° to 30°, whereas the vertebral wedging at curve apices progressed from 5° to 12°. With the hemistaple Config 1, the Cobb angles progressed but were limited to 42° and 26°, whereas the wedging ended at 8°. With Config 3, Cobb and wedging were kept nearly constant (38°, 21°, 7°). With hemistaples on both endplates (Config 2, Config 4), the Cobb and wedging were all reduced (thoracic Cobb for Config 2 and 4: 24° and 15°; lumbar Cobb: 21° and 11°; wedging: 2° and 1°). Conclusion. This study suggests that the hemistaple has the biomechanical potential to control the scoliosis progression and highlights the importance of the instrumentation configuration to correct the spinal deformities. It biomechanically supports the new fusionless device concept as an alternative for the early treatment of idiopathic scoliosis.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84952914229&origin=inward; http://dx.doi.org/10.1097/brs.0000000000000777; http://www.ncbi.nlm.nih.gov/pubmed/25584943; http://content.wkhealth.com/linkback/openurl?sid=WKPTLP:landingpage&an=00007632-201503150-00005; http://journals.lww.com/00007632-201503150-00005; http://dx.doi.org/10.1097/BRS.0000000000000777; https://insights.ovid.com/article/00007632-201503150-00005