Combining bilateral magnetically controlled implants inserted parallel to the spine with rib to pelvis fixation: Surgical technique and early results
Clinical Spine Surgery, ISSN: 2380-0194, Vol: 31, Issue: 6, Page: 239-246
2018
- 19Citations
- 29Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations19
- Citation Indexes19
- 19
- CrossRef16
- Captures29
- Readers29
- 29
Article Description
Spine-based fixation of magnetically controlled lengthening devices has been successfully performed for children with early-onset scoliosis. However, spinal manipulation may lead to ossifications, stiffness, and autofusion as previously described. To avoid these problems, a surgical technique combining bilateral externally controlled magnetic device implantation with a rib cradle and pelvic hook fixation was introduced by us in 2011. By using a bilateral single-rib or double-rib cradle fixation and a pelvic hook, the magnetic device is percutaneously inserted. The spine corrects indirectly without further manipulation. In small rib diameter or severe osteoporosis, double-rib cradles are used. Our introduced technique enables modification of the rib vertebral angle, which may be beneficial in children with spinal muscular atrophy and rib-cage deformity. This nonrandomized prospective study describes 18 children with neuromuscular scoliosis treated first by this method. All patients followed the same protocol, with expansion procedures being performed 5 months after surgery and every 3 months thereafter. Clinical, radiologic, and complication data were analyzed, showing a significant reduction in scoliosis and pelvic obliquity and an increase in spinal length, which could be maintained over a follow-up period of 1.2 years. The overall complication rate was lower than previously described, with 8%, 2 of them requiring surgery.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85041555773&origin=inward; http://dx.doi.org/10.1097/bsd.0000000000000614; http://www.ncbi.nlm.nih.gov/pubmed/29369154; https://journals.lww.com/01933606-201807000-00003; https://dx.doi.org/10.1097/bsd.0000000000000614; https://insights.ovid.com/crossref?an=01933606-201807000-00003
Ovid Technologies (Wolters Kluwer Health)
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know