Are Observational Studies on Distal Radius Fracture Treatment Robust? An E-value Approach to Analysis
Clinical Orthopaedics and Related Research, ISSN: 1528-1132, Vol: 481, Issue: 6, Page: 1174-1192
2023
- 2Citations
- 5Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Review Description
BackgroundReported complication frequencies after distal radius fracture (DRF) treatment vary widely in the literature and are based mostly on observational evidence. Whether that evidence is sufficiently robust to use in practice is controversial. The E-value is an innovative sensitivity analysis that quantitates the robustness of observational evidence against unmeasured confounders, whereby a greater E-value usually implies more robust evidence and vice versa; with DRF complications, this approach can help guide readers to a more confident interpretation of the available evidence.Questions/purposesIn this study, we sought (1) to compare the complication frequencies among different DRF treatment modalities, and (2) to evaluate the robustness of these observational studies using the E-value as an index for unmeasured confounding.MethodsWe searched PubMed, Embase, and SCOPUS for observational studies on the management of DRFs that were published from January 2001 to July 2021 with the last database search performed on July 31, 2021. All articles that compared different DRF treatment modalities with reported complication frequencies were included to accurately capture the quality of the observational studies in research about DRF. Risk ratios (RRs) of the overall complication and major complication risks were calculated for each subgroup comparison: volar plating versus dorsal plating, casting, external fixation, and percutaneous K-wire fixation. The RRs and their corresponding lower limits of the 95% confidence intervals (CIs) were used to derive the E-values. E-values can have a minimum possible value of 1, which signifies that the treatment-outcome association is not strong and can readily be overturned by unmeasured confounders. By contrast, a large E-value means that the observed treatment-outcome association is robust against unmeasured confounders. We averaged RRs and E-values for the effect estimates and lower limits of CIs across studies in each treatment comparison group. We identified 36 comparative observational studies that met the inclusion criteria. Seven studies compared volar with dorsal plating techniques. Volar plating was also compared with casting (eight studies), external fixation (15 studies), and percutaneous K-wire fixation (six studies).ResultsTotal and major complication risks did not differ among different DRF treatments. The mean RRs for total and major complications were 1.2 (95% CI 0.4 to 3.9; p = 0.74) and 1.8 (95% CI 0.4 to 11.4; p = 0.52) for the volar versus dorsal plating group; 1.2 (95% CI 0.3 to 11.2; p = 0.87) and 1.5 (95% CI 0.3 to 14.9; p = 0.74) for the volar plating versus casting group; 0.6 (95% CI 0.2 to 2.2; p = 0.33) and 0.8 (95% CI 0.2 to 6.7; p = 0.86) for the volar plating versus external fixation group; and 0.6 (95% CI 0.2 to 2.6; p = 0.47) and 0.7 (95% CI 0.2 to 4.0; p = 0.67) for the volar plating versus K-wire fixation group. The mean E-values for total and major complication frequencies for the between-group comparison ranged from 3.1 to 5.8; these were relatively large in the context of a known complication risk factor, such as high-energy impact (RR 3.2), suggesting a reasonable level of robustness against unmeasured confounding. However, the E-values for lower limits of CIs remained close to 1, which indicates the observed complication frequencies in these studies were likely to have been influenced by unmeasured confounders.ConclusionComplication frequencies did not differ among different DRF treatment modalities, but the observed complication frequencies from most comparative observational studies were less robust against potential unmeasured confounders. The E-value method, or another type of sensitivity analysis, should be implemented in observational hand surgery research at the individual-study level to facilitate assessment of robustness against potential unmeasured confounders.Level of EvidenceLevel III, therapeutic study.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85159775010&origin=inward; http://dx.doi.org/10.1097/corr.0000000000002528; http://www.ncbi.nlm.nih.gov/pubmed/36728049; https://journals.lww.com/10.1097/CORR.0000000000002528; https://dx.doi.org/10.1097/corr.0000000000002528; https://journals.lww.com/clinorthop/abstract/2023/06000/are_observational_studies_on_distal_radius.21.aspx
Ovid Technologies (Wolters Kluwer Health)
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know