Point-of-care prothrombin time testing in paediatric intensive care: An observational study of the ease of use of two devices
European Journal of Anaesthesiology, ISSN: 0265-0215, Vol: 29, Issue: 2, Page: 75-81
2012
- 11Citations
- 16Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations11
- Citation Indexes10
- 10
- CrossRef8
- Policy Citations1
- Policy Citation1
- Captures16
- Readers16
- 16
Article Description
Background Two major difficulties arise when taking blood samples in children: the challenge of venous access and the comparatively large amount of blood required. Objective To assess the value of point-of-care prothrombin time testing in paediatric intensive care patients. We evaluated two point-of-care devices, CoaguChek XS Plus and CoaLine, assessing ease of use in clinical practice and correlation with the standard prothrombin time measurement of the haematology laboratory. Design Single-centre observational study. Setting Between October 2007 and March 2008, patients in an interdisciplinary paediatric ICU of a tertiary centre were analysed. Patients or other participants Thirty-eight patients, 22 female and 16 male (58 and 42%), aged between 0 and 13 years, participated in the study. The intention was to evaluate the ease of use of the devices in daily clinical practice, and no exclusion criteria were applied. Main outcome measures The usefulness of the two point-ofcare devices in the paediatric setting was evaluated. Measurements of point-of-care and standard laboratory prothrombin time were compared in terms of agreement and correlation. Results CoaguChek XS Plus had a failure rate of 2%, CoaLine 17% and the laboratory standard 4%. CoaguChek XS Plus received a better ease of use rating than CoaLine by the study personnel. Compared with the laboratory standard, there was considerable variability of the observed measurements with both devices. The measurements of CoaguChek XS Plus and the standard had a correlation coefficient r of being 0.79. CoaLine and the standard had a correlation coefficient r value of 0.72. Conclusion CoaguChek XS Plus showed 'good' agreement, whereas CoaLine showed 'moderate' agreement compared with prothrombin time values using the standard method. The fast availability of results and the reduction of the required blood volume are advantages of point-of-care tests in the paediatric setting. © 2012 Copyright European Society of Anaesthesiology.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84859771312&origin=inward; http://dx.doi.org/10.1097/eja.0b013e32834b7d65; http://www.ncbi.nlm.nih.gov/pubmed/22012176; http://journals.lww.com/00003643-201202000-00004; http://content.wkhealth.com/linkback/openurl?sid=WKPTLP:landingpage&an=00003643-201202000-00004; https://dx.doi.org/10.1097/eja.0b013e32834b7d65; https://journals.lww.com/ejanaesthesiology/Fulltext/2012/02000/Point_of_care_prothrombin_time_testing_in.4.aspx