Evaluation of broadband spectral transmission characteristics of fresh and gamma-irradiated corneal tissues
Cornea, ISSN: 1536-4798, Vol: 34, Issue: 2, Page: 228-234
2015
- 10Citations
- 12Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations10
- Citation Indexes10
- 10
- CrossRef8
- Captures12
- Readers12
- 12
Article Description
Purpose: The aim of this study was to evaluate the clarity of gamma-irradiated sterile corneal donor lenticules. Methods: Broadband UV, visible, and near-infrared (200-850 nm) light transmission was measured through gamma-irradiated, sterile partial-thickness, and full-thickness donor lenticules and fresh corneal tissues and compared with standard acrylic intraocular lens (IOL) implants using a conventional spectrophotometer technique. Results: All tissues had high light transmission (≥ 90%) in the visible and near-infrared regions and very low (<2%) transmission below 290 nm. Differences in light transmission between irradiated and fresh cornea types were observed between 300 and 450 nm, which mirrored differences in light transmission through their respective storage solutions. Light transmission through partial-thickness irradiated donor lenticules was greatest across all wavelengths. All corneal tissues exhibited higher transmission than acrylic IOL implant across all wavelengths. Conclusions: Gamma-irradiated donor lenticules are comparable with fresh corneas regarding light transmission, with both partialthickness and full-thickness lenticules having greater transmission than standard IOL. We would expect the optical performance of gammairradiated donor lenticules to be comparable to fresh cornea if used for lamellar corneal procedures that do not require a viable endothelium.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84925826917&origin=inward; http://dx.doi.org/10.1097/ico.0000000000000323; http://www.ncbi.nlm.nih.gov/pubmed/25522222; http://content.wkhealth.com/linkback/openurl?sid=WKPTLP:landingpage&an=00003226-201502000-00014; https://journals.lww.com/00003226-201502000-00014; https://dx.doi.org/10.1097/ico.0000000000000323; https://insights.ovid.com/article/00003226-201502000-00014
Ovid Technologies (Wolters Kluwer Health)
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know