Two-Year Outcomes of the New Low-cost Nonvalved Aurolab Aqueous Drainage Implant in Refractory Glaucoma
Journal of Glaucoma, ISSN: 1536-481X, Vol: 29, Issue: 9, Page: 767-772
2020
- 12Citations
- 8Captures
- 1Mentions
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations12
- Citation Indexes12
- 12
- CrossRef9
- Captures8
- Readers8
- Mentions1
- News Mentions1
- News1
Most Recent News
Nonvalved aqueous drainage implant reduces IOP, glaucoma medications
A low-cost nonvalved aqueous drainage implant significantly reduced IOP and glaucoma medication use in patients with refractory glaucoma, according to a retrospective review. “The design inspiration of this cost-effective indigenously manufactured nonvalved device is the Baerveldt glaucoma implant (Johnson & Johnson Vision), which is not available in India. Its performance appears to be rather sim
Article Description
Purpose:This study aimed to report the 2-year surgical outcomes in terms of efficacy and safety of the relatively new, indigenously manufactured, low-cost nonvalved drainage device Aurolab Aqueous Drainage Implant (AADI) in the management of refractory glaucomas in the Indian population.Methods:A retrospective review of consecutive patients older than 12 years, who underwent nonvalved glaucoma drainage device surgery via AADI, was performed by a single fellowship-trained surgeon, between January 2014 and January 2018, who had at least 12 months of documented postoperative follow-up.Outcome Measures:Primary - intraocular pressure (IOP).Secondary - number of antiglaucoma medication (AGM), LogMAR best-corrected visual acuity and complications.Complete success was defined as IOP ≥5 and ≤21 mm Hg; qualified success was defined as fulfilling the above criteria with the use of AGM. Failure was defined as the inability to fulfill the IOP criteria, loss of perception of light, explantation, or any additional glaucoma surgery.Results:A total of 48 eyes of 46 patients were included with a median follow-up of 24 months (quartile 1=16, quartile 3=31.25; interquartile range=15.25) (mean=24.9 mo; SD=10.1). The IOP and number of AGM required was significantly lower at every timepoint postoperatively (P<0.001). The median LogMAR best-corrected visual acuity remained unchanged (P=0.307). Complications occurred in 21 patients (43.7%); some eyes had >1 complication. Complete success was seen in 56.3%; overall success was 87.5%.Conclusions:The safety and efficacy of the new nonvalved glaucoma drainage device, AADI, remain in its second year after implantation. Still further follow-up is recommended, as it has the ability to breach the cost barrier in newly industrialized nations worldwide.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85086156774&origin=inward; http://dx.doi.org/10.1097/ijg.0000000000001532; http://www.ncbi.nlm.nih.gov/pubmed/32366777; https://journals.lww.com/10.1097/IJG.0000000000001532; https://dx.doi.org/10.1097/ijg.0000000000001532; https://journals.lww.com/glaucomajournal/Abstract/9000/Two_year_Outcomes_of_the_New_Low_cost_Non_valved.97896.aspx