Optical skill-assist device for ultrasound-guided vascular access: A preliminary simulation study
Medicine, ISSN: 1536-5964, Vol: 98, Issue: 26, Page: e16126-null
2019
- 4Citations
- 37Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations4
- Citation Indexes4
- CrossRef4
- Captures37
- Readers37
- 27
- 10
Article Description
Ultrasound-guided central venous catheterization may cause lethal mechanical complications intraoperatively. We developed a novel device to prevent such complications. It works as a needle guide to supplement the operator's skill. We evaluated the utility of this device in terms of the success rate and visualization of the needle tip while penetrating the target vessel using a simulator.This study was approved by the local ethics committee. The new device - an optical skill-assist device - has a slit and a mirror in the center. The operator can see the needle's reflection in the mirror through the slit and can thus ensure that the needle is directed in line with the ultrasound beam. Participants were recruited by placing an advertisement for a hands-on seminar on ultrasound-guided vascular access. They received hands-on training on the in-plane approach for 2 hours. Pre-test and post-test without the device and an additional test using the device were performed to evaluate the proficiency of ultrasound-guided vascular access. An endoscope inserted into the simulated vessel was used to detect the precise location of the needle tip in the vessel.The primary outcomes were the success rate of the procedure. The secondary outcome was visualization of the needle tip while penetrating the simulated vessel. The chi-squared test was used for comparing the success rate and needle tip visualization between the different tests. P < .05 was considered to indicate significant differences.Forty-two participants were enrolled in this study. The success rate did not increase after the simulation training (P = .1). Using the optical skill-assist device, the rate improved to 100%. There was a significant difference in success rate between the pre-test and additional test using the optical skill-assist device (P = .003). Needle tip visualization significantly improved with the use of the optical skill-assist device compared to the pre-test (P < .001) and post-test (P = .001).Simulation training improved participants' skill for ultrasound-guided vascular access, but the improvement depended on each participant. However, further, improvement was achieved with the use of the optical skill-assist device.The optical skill-assist device is useful for supplementing the operator's skill for ultrasound-guided central venous catheterization.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85069269651&origin=inward; http://dx.doi.org/10.1097/md.0000000000016126; http://www.ncbi.nlm.nih.gov/pubmed/31261532; https://journals.lww.com/00005792-201906280-00043; https://dx.doi.org/10.1097/md.0000000000016126; https://insights.ovid.com/crossref?an=00005792-201906280-00043
Ovid Technologies (Wolters Kluwer Health)
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know