PlumX Metrics
Embed PlumX Metrics

Value of Tc-MIBI SPECT/CT in the localization of recurrent lesions in patients with suspected recurrent parathyroid carcinoma

Nuclear Medicine Communications, ISSN: 1473-5628, Vol: 44, Issue: 1, Page: 18-26
2023
  • 2
    Citations
  • 0
    Usage
  • 4
    Captures
  • 1
    Mentions
  • 0
    Social Media
Metric Options:   Counts1 Year3 Year

Metrics Details

Most Recent News

Studies from Capital Medical University Update Current Data on Thyroid Cancer (Value of Tc-99m-mibi Spect/ct In the Localization of Recurrent Lesions In Patients With Suspected Recurrent Parathyroid Carcinoma)

2023 JAN 25 (NewsRx) -- By a News Reporter-Staff News Editor at NewsRx Medical Devices Daily -- Investigators publish new report on Oncology - Thyroid

Article Description

Purpose Accurate preoperative localization of tumor-bearing lesions is crucial for the successful surgical management of suspected recurrent parathyroid carcinoma. The purpose of this study was to evaluate the diagnostic value of 99m-technetium-labeled methoxyisobutylisonitrile (Tc-MIBI) single-photon emission computed tomography/computed tomography (SPECT/CT) and cervical ultrasound, individually and in combination, for preoperative localization of recurrent/metastatic lesions. We also analyzed the value of Tc-MIBI SPECT/CT in detecting ectopic lesions in patients with suspected recurrent parathyroid carcinoma. Methods Twenty-nine patients with suspected recurrent parathyroid carcinoma were included in this retrospective cohort study. Patients underwent preoperative Tc-MIBI SPECT/CT and cervical ultrasound. The reference standard was postsurgical histopathology. The sensitivity, specificity, positive predictive value (PPV), negative predictive value, and accuracy of the two diagnostic modalities alone and in combination were analyzed. Results Of the 29 patients, histopathological results revealed 48 metastases/recurrent lesions in 26 patients. The diagnostic value of Tc-MIBI SPECT/CT, cervical ultrasound, and the two modalities in combination were compared for the 27 patients who underwent new cervical surgery. Patient-level analysis of the combined use of Tc-MIBI SPECT/CT and cervical ultrasound had the highest sensitivity (100.00%) and accuracy (96.30%). At the lesion level, Tc-MIBI SPECT/CT had the highest specificity and PPV, at 100.00% respectively, whereas the combined use of Tc-MIBI SPECT/CT and cervical ultrasound had the highest sensitivity, at 97.62%. Moreover, Tc-MIBI SPECT/CT detected six ectopic lesions, and five of them showed increased Tc-MIBI uptake. Conclusions The combined use of Tc-MIBI SPECT/CT and cervical ultrasound is the most efficient strategy in the diagnosis of parathyroid carcinoma relapse, whereas Tc-MIBI SPECT/CT is the preferred method for localizing and analyzing cervical and extra-cervical lesions before the new surgery.

Provide Feedback

Have ideas for a new metric? Would you like to see something else here?Let us know