Visual performance of a multifocal toric soft contact lens
Optometry and Vision Science, ISSN: 1040-5488, Vol: 89, Issue: 11, Page: 1627-1635
2012
- 13Citations
- 40Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations13
- Citation Indexes13
- 13
- CrossRef11
- Captures40
- Readers40
- 40
Article Description
PURPOSE: To evaluate the visual performance of the Proclear multifocal toric contact lens (CL; CooperVision, US) for both presbyopia and astigmatism correction. METHODS: In this crossover study design, 20 presbyopic subjects with astigmatism were fitted in a random order with either Proclear multifocal toric CL or Proclear toric single vision distance CL (DCL) combined with reading spectacles. After 1 month, high-contrast distance visual acuity, near high-contrast visual acuity, distance contrast sensitivity (CS) under photopic and mesopic conditions without and with glare, near CS, defocus curve, and stereopsis were measured. Subjects were then refitted with the alternative correction, and the procedure was repeated. RESULTS: Repeated measures analysis of variance revealed differences in visual acuity and CS (p < 0.001) between groups. Mean binocular distance visual acuity and near visual acuity obtained with multifocal toric CL were -0.01 ± 0.03 logMAR and -0.04 ± 0.06 logMAR, respectively. The mean distance CS with the multifocal toric CL was within normal limits under photopic and mesopic conditions. Under photopic conditions, distant CS was better with distance CL than with multifocal toric CL only at 18 cycles/degree. Under mesopic conditions without and with glare, there were differences between both CLs in distant CS for all spatial frequencies. There were differences between the two CLs in near CS for all spatial frequencies. Mean values of stereopsis obtained with multifocal toric CLs and with the DCL combined with reading glasses were 62 ± 12 sec of arc and 59 ± 12 sec of arc, respectively (p = 0.06). Near range of clear vision with the multifocal toric CLs was 1.55 ± 0.33D. CONCLUSIONS: The results of this study suggest that the multifocal toric CL studied is a good option to compensate both presbyopia and astigmatism, providing an optimal distance and near visual quality without compromising the stereopsis. Copyright © 2012 American Academy of Optometry.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84869861865&origin=inward; http://dx.doi.org/10.1097/opx.0b013e31826b0934; http://www.ncbi.nlm.nih.gov/pubmed/23034336; http://content.wkhealth.com/linkback/openurl?sid=WKPTLP:landingpage&an=00006324-201211000-00012; https://journals.lww.com/00006324-201211000-00012; https://dx.doi.org/10.1097/opx.0b013e31826b0934; https://insights.ovid.com/article/00006324-201211000-00012
Ovid Technologies (Wolters Kluwer Health)
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know