Deformable anatomic templates embed knowledge into brain images: Part 2. Validation using functional magnetic resonance imaging of the motor hand
Journal of Computer Assisted Tomography, ISSN: 1532-3145, Vol: 36, Issue: 2, Page: 280-284
2012
- 6Citations
- 14Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations6
- Citation Indexes6
- CrossRef4
- Captures14
- Readers14
- 13
Correction Description
OBJECTIVE: This study evaluated the concordance between the Deformable Anatomic Template (DAT)-identified origin of motor hand fibers and localization of the motor cortex of the hand by functional magnetic resonance imaging (fMRI). METHODS: Preoperative fMRI during hand motor tasks was performed on 36 hemispheres in 26 patients with gliomas in or near eloquent areas. Reformatted volume-rendered surface images were labeled with the DAT's hand motor fibers and fMRI data. Five reviewers assessed the data for concordance. RESULTS: Available fMRI data were diagnostically usable in 92% (33/36 analyzed hemispheres), with DAT anatomic accuracy in the remaining cases. The DAT prediction and fMRI findings were concordant in all 9 normal hemispheres and in 20 (83%) of 24 glioma-bearing hemispheres. The 4 discordant cases resulted from substantial mass effect by large frontal tumors. CONCLUSIONS: This study validated DAT's anatomic atlas and alignment process for the expected position of the motor cortex of the hand. © 2012 Lippincott Williams & Wilkins, Inc.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84859191158&origin=inward; http://dx.doi.org/10.1097/rct.0b013e318245c21b; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84859166542&origin=inward; http://www.ncbi.nlm.nih.gov/pubmed/22446375; http://content.wkhealth.com/linkback/openurl?sid=WKPTLP:landingpage&an=00004728-201203000-00024; http://journals.lww.com/00004728-201203000-00024; https://dx.doi.org/10.1097/rct.0b013e318245c21b; https://journals.lww.com/jcat/Abstract/2012/03000/Deformable_Anatomic_Templates_Embed_Knowledge_Into.24.aspx
Ovid Technologies (Wolters Kluwer Health)
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know