Steady-State Cortico-Cortical Evoked Potential
Journal of Clinical Neurophysiology, ISSN: 1537-1603, Vol: 40, Issue: 4, Page: 301-309
2023
- 6Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Captures6
- Readers6
Article Description
Purpose:The present study evaluated the utility of the steady-state responses of cortico-cortical evoked potentials (SSCCEPs) and compared them with the responses of conventional CCEPs.Methods:Eleven patients with medically intractable focal epilepsy who underwent the implantation of subdural electrodes or stereoelectroencephalography were enrolled. Conventional CCEPs were obtained by averaging responses to alternating 1-Hz electrical stimuli, and 5-Hz stimuli were delivered for recording SSCCEPs. The distribution of SSCCEPs was assessed by a frequency analysis of fast Fourier transform and compared with conventional CCEPs.Results:Steady-state responses of cortico-cortical evoked potentials were successfully recorded in areas consistent with conventional CCEPs in all patients. However, SSCCEPs were more easily disturbed by the 5-Hz stimulation, and small responses had difficulty generating SSCCEPs.Conclusions:Steady-state responses of cortico-cortical evoked potentials may be a useful alternative to conventional CCEPs.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85159553566&origin=inward; http://dx.doi.org/10.1097/wnp.0000000000000887; http://www.ncbi.nlm.nih.gov/pubmed/34387274; https://journals.lww.com/10.1097/WNP.0000000000000887; https://dx.doi.org/10.1097/wnp.0000000000000887; https://journals.lww.com/clinicalneurophys/abstract/2023/05000/steady_state_cortico_cortical_evoked_potential.4.aspx
Ovid Technologies (Wolters Kluwer Health)
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know