Contact dynamics of massage compliant robotic arm and its coupled stability
Proceedings - IEEE International Conference on Robotics and Automation, ISSN: 1050-4729, Page: 1499-1504
2014
- 11Citations
- 25Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Conference Paper Description
In this paper, contact dynamics of robot massage is described by the port-Hamiltonian modelling approach. In order to capture accurately the inherent characteristics of the human body in lumped-parameter manners, the conventional linear Kelvin-Voigt models are replaced by the nonlinear Hunt-Crossley models. As an application of the contact dynamics, coupled stability of compliant robotic arm with impedance control is theoretically analyzed from energetic viewpoints. Experiments are done to verify the massage stability. The proposed contact dynamics evidently has great potential on performance improvement of robot massage, which will be our research subject.