Agreement between clinical and laboratory methods assessing tonic and cross-link components of accommodation and vergence
Clinical and Experimental Optometry, ISSN: 1444-0938, Vol: 98, Issue: 5, Page: 435-446
2015
- 6Citations
- 17Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations6
- Citation Indexes6
- CrossRef3
- Captures17
- Readers17
- 17
Article Description
Background: Several tests are available to optometrists for investigating accommodation and vergence. This study sought to investigate the agreement between clinical and laboratory methods and to clarify which components are actually measured when tonic and cross-link of accommodation and vergence are assessed. Methods: Tonic vergence, tonic accommodation, accommodative vergence (AC/A) and vergence accommodation (CA/C) were measured using several tests. Clinical tests were compared to the laboratory assessment, the latter being regarded as an absolute reference. The repeatability of each test and the degree of agreement between the tests were quantified using Bland-Altman analysis. Results: The values obtained for each test were found to be stable across repetitions; however, in most cases, significant differences were observed between tests supposed to measure the same oculomotor component. Tonic and cross-link components cannot be easily assessed because proximal and instrumental responses interfere with the assessment. Other components interfere with oculomotor assessment. Specifically, accommodative divergence interferes with tonic vergence estimation and the type of accommodation considered in the AC/A ratio affects its magnitude. Results on clinical tonic accommodation and clinical CA/C show that further investigation is needed to clarify the limitations associated with the use of difference of Gaussian as visual targets to open the accommodative loop. Conclusions: Although different optometric tests of accommodation and vergence rely on the same basic principles, the results of this study indicate that clinical and laboratory methods actually involve distinct components. These differences, which are induced by methodological choices, must be taken into account, when comparing studies or when selecting a test to investigate a particular oculomotor component.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84941948853&origin=inward; http://dx.doi.org/10.1111/cxo.12311; http://www.ncbi.nlm.nih.gov/pubmed/26390906; https://www.tandfonline.com/doi/full/10.1111/cxo.12311; https://dx.doi.org/10.1111/cxo.12311; https://onlinelibrary.wiley.com/doi/full/10.1111/cxo.12311
Informa UK Limited
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know