The successful DNA typing of samples following a thermal cycler power loss
Journal of Forensic Sciences, ISSN: 0022-1198, Vol: 51, Issue: 5, Page: 1074-1079
2006
- 3Citations
- 11Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Conference Paper Description
An approach for generating DNA profiles when critical samples have been consumed and a power outage occurs during the polymerase chain reaction (PCR) amplification reaction is described. This study demonstrates that a complete and accurate DNA short tandem repeat profile can be obtained: (1) when single source DNA samples are amplified for 26, 27, or 28 cycles using the Profiler Plus and COfiler Amplification Kits after an interruption in amplification, (2) from mock samples when PCR amplification has been interrupted early (after five cycles) or late (after 18 cycles) and the sample is subjected to an additional round of amplification, even after incubation of the sample at room temperature overnight, and (3) from nonprobative casework samples interrupted after approximately 18 cycles of amplification, an overnight incubation at room temperature and subjected to one or two additional rounds of PCR amplification for approximately 26 total cycles. Samples interrupted before five completed cycles and subjected to additional PCR cycles yielded variable results. Copyright © 2006 by American Academy of Forensic Sciences.
Bibliographic Details
Wiley
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know