Development of loop-mediated isothermal amplification assay for the detection of Pythium myriotylum
Letters in Applied Microbiology, ISSN: 1472-765X, Vol: 59, Issue: 1, Page: 49-57
2014
- 34Citations
- 36Captures
- 2Mentions
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations34
- Citation Indexes34
- 34
- CrossRef27
- Captures36
- Readers36
- 36
- Mentions2
- References2
- Wikipedia2
Article Description
This study reports the development of a loop-mediated isothermal amplification (LAMP) reaction for the detection of Pythium myriotylum. The primer set targeting the ITS sequence of P. myriotylum worked most efficiently at 60°C and allowed the detection of P. myriotylum DNA within 30 min by fluorescence monitoring using a real-time PCR instrument. The peak denaturing temperature of amplified DNA was about 87·0°C. In specificity tests using eight Pythium myriotylum strains, 59 strains from 39 species of Pythium, 11 Phytophthora strains and eight other soil-borne pathogens, LAMP gave no cross-reactions. The detection limit was 100 fg of genomic DNA, which was as sensitive as PCR. LAMP could detect P. myriotylum in hydroponic solution samples, and the results coincided with those of the conventional plating method in almost all cases. The LAMP method established in this study is a simple and sensitive tool for the detection of P. myriotylum. © 2014 The Society for Applied Microbiology.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84902317234&origin=inward; http://dx.doi.org/10.1111/lam.12244; http://www.ncbi.nlm.nih.gov/pubmed/24612040; https://academic.oup.com/lambio/article/59/1/49/6699782; https://dx.doi.org/10.1111/lam.12244; https://academic.oup.com/lambio/article-abstract/59/1/49/6699782?redirectedFrom=fulltext
Oxford University Press (OUP)
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know