Applications of a new handheld reference point indentation instrument measuring bone material strength
Journal of Medical Devices, Transactions of the ASME, ISSN: 1932-6181, Vol: 7, Issue: 4, Page: 410051-410056
2013
- 62Citations
- 68Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations62
- Citation Indexes62
- 62
- CrossRef50
- Captures68
- Readers68
- 68
Article Description
A novel, hand-held Reference Point Indentation (RPI) instrument, measures how well thebone of living patients and large animals resists indentation. The results presented hereare reported in terms of Bone Material Strength, which is a normalized measure of howwell the bone resists indentation, and is inversely related to the indentation distance intothe bone. We present examples of the instrument's use in: (1) laboratory experiments onbone, including experiments through a layer of soft tissue, (2) three human clinical trials,two ongoing in Barcelona and at the Mayo Clinic, and one completed in Portland, OR,and (3) two ongoing horse clinical trials, one at Purdue University and another at AlamoPintado Stables in California. The instrument is capable of measuring consistent valueswhen testing through soft tissue such as skin and periosteum, and does so handheld, animprovement over previous Reference Point Indentation instruments. Measurements conductedon horses showed reproducible results when testing the horse through tissue or onbare bone. In the human clinical trials, reasonable and consistent values were obtained,suggesting the OsteoprobeVR is capable of measuring Bone Material Strength in vivo, butlarger studies are needed to determine the efficacy of the instrument's use in medical diagnosis.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84885079143&origin=inward; http://dx.doi.org/10.1115/1.4024829; http://www.ncbi.nlm.nih.gov/pubmed/24115973; https://asmedigitalcollection.asme.org/medicaldevices/article/doi/10.1115/1.4024829/376672/Applications-of-a-New-Handheld-Reference-Point; https://dx.doi.org/10.1115/1.4024829; https://asmedigitalcollection.asme.org/medicaldevices/article-abstract/7/4/041005/376672/Applications-of-a-New-Handheld-Reference-Point?redirectedFrom=fulltext; https://ohsu.pure.elsevier.com/en/publications/7a4f34dd-e61e-4bcb-b3e5-49b291c4b396; http://medicaldevices.asmedigitalcollection.asme.org/data/journals/jmdoa4/927704/med_007_04_041005.pdf; https://asmedigitalcollection.asme.org/medicaldevices/article-pdf/7/4/041005/6235278/med_007_04_041005.pdf; http://asmedigitalcollection.asme.org/medicaldevices/article-pdf/doi/10.1115/1.4024829/6235278/med_007_04_041005.pdf; http://medicaldevices.asmedigitalcollection.asme.org/article.aspx?doi=10.1115/1.4024829; http://medicaldevices.asmedigitalcollection.asme.org/article.aspx?articleid=1742992
ASME International
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know