Probabilistic method for context-sensitive detection of polyps in CT colonography
Progress in Biomedical Optics and Imaging - Proceedings of SPIE, ISSN: 1605-7422, Vol: 7963, Page: 10.1117/12.878207
2011
- 1Citations
- 18Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Conference Paper Description
Radiologists can outperform computer-aided detection (CAD) systems for CT colonography, because they consider not only local characteristics but also the context of findings. In particular, isolated findings are considered as more suspicious than clustered ones. We developed a computational method to model this problem-solving technique for reducing false-positive (FP) CAD detections in CT colonography. Lesion likelihood was estimated from shape and texture features of each candidate detection by use of a Bayesian neural network. Context features were calculated to characterize the distribution of candidate detections in a local neighborhood. A belief network was applied to detect isolated candidates at a higher sensitivity than clustered ones. The detection performances of the context-sensitive CAD and a conventional CAD were compared by use of leave-one-patient-out evaluation on 73 patients. Conventional CAD detected 82% of the lesions 6 - 9 mm in size with a median of 6 false positives per CT scan, whereas context-sensitive CAD detected the lesions at a median of 4 false positives with significant increment in overall detection performance. For lesions ≥10 mm in size, the detection sensitivity was 98% with a median of 7 false positives per patient, but the improvement in detection performance was not significant. © 2011 SPIE.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=79955752229&origin=inward; http://dx.doi.org/10.1117/12.878207; http://www.ncbi.nlm.nih.gov/pubmed/24665192; http://proceedings.spiedigitallibrary.org/proceeding.aspx?doi=10.1117/12.878207; https://dx.doi.org/10.1117/12.878207; https://www.spiedigitallibrary.org/access-suspended
SPIE-Intl Soc Optical Eng
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know