Pulmonary compliance in sick low birthweight Infants: How reliable is the measurement of oesophageal pressure?
Archives of Disease in Childhood, ISSN: 0003-9888, Vol: 58, Issue: 11, Page: 891-896
1983
- 41Citations
- 4Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations41
- Citation Indexes40
- CrossRef40
- 35
- Policy Citations1
- 1
- Captures4
- Readers4
Article Description
Measurements of dynamic lung compliance (Cdyn) were made on 42 occasions in a group of 15 intubated very low birthweight infants with respiratory distress syndrome, using an oesophageal balloon and pneumotachograph system. Values of Cdyn were compared with those of total respiratory system compliance (Crs) using an occlusion technique. Ten very low birthweight infants with no respiratory disease were similarly studied while breathing through a facemask. The occlusion tests for oesophageal balloon assessment were unsatisfactory in 14 of 15 intubated infants, but in only 3 of the 10 normal infants. Values of Cdyn were poorly reproducible and correlated poorly with Crs. We conclude that in sick intubated preterm infants oesophageal pressure (and hence Cdyn) cannot be reliably measured, but that Crs may be a useful parameter of lung stiffness.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=0021089963&origin=inward; http://dx.doi.org/10.1136/adc.58.11.891; http://www.ncbi.nlm.nih.gov/pubmed/6651326; https://adc.bmj.com/lookup/doi/10.1136/adc.58.11.891; https://dx.doi.org/10.1136/adc.58.11.891; https://adc.bmj.com/content/58/11/891
BMJ