Reliability of wireless monitoring using a wearable patch sensor in high-risk surgical patients at a step-down unit in the Netherlands: A clinical validation study
BMJ Open, ISSN: 2044-6055, Vol: 8, Issue: 2, Page: e020162
2018
- 90Citations
- 215Captures
- 1Mentions
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations90
- Citation Indexes90
- CrossRef90
- 89
- Captures215
- Readers215
- 215
- Mentions1
- News Mentions1
- 1
Most Recent News
Integrated Proactive Wireless Monitoring for Clinical Deterioration: A Stepped Wedge Randomized Trial
2024 OCT 25 (NewsRx) -- By a News Reporter-Staff News Editor at NewsRx Cardiovascular Daily -- Staff editors report on the newly launched clinical trial,
Article Description
Background and objectives Intermittent vital signs measurements are the current standard on hospital wards, typically recorded once every 8 hours. Early signs of deterioration may therefore be missed. Recent innovations have resulted in 'wearable' sensors, which may capture patient deterioration at an earlier stage. The objective of this study was to determine whether a wireless ' patch' sensor is able to reliably measure respiratory and heart rate continuously in high-risk surgical patients. The secondary objective was to explore the potential of the wireless sensor to serve as a safety monitor. Design In an observational methods comparisons study, patients were measured with both the wireless sensor and bedside routine standard for at least 24 hours. Setting University teaching hospital, single centre. Participants Twenty-five postoperative surgical patients admitted to a step-down unit. Outcome measures Primary outcome measures were limits of agreement and bias of heart rate and respiratory rate. Secondary outcome measures were sensor reliability, defined as time until first occurrence of data loss. Results 1568 hours of vital signs data were analysed. Bias and 95% limits of agreement for heart rate were '1.1 ('8.8 to 6.5) beats per minute. For respiration rate, bias was '2.3 breaths per minute with wide limits of agreement ('15.8 to 11.2 breaths per minute). Median filtering over a 15 min period improved limits of agreement of both respiration and heart rate. 63% of the measurements were performed without data loss greater than 2 min. Overall data loss was limited (6% of time). Conclusions The wireless sensor is capable of accurately measuring heart rate, but accuracy for respiratory rate was outside acceptable limits. Remote monitoring has the potential to contribute to early recognition of physiological decline in high-risk patients. Future studies should focus on the ability to detect patient deterioration on low care environments and at home after discharge.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85052787285&origin=inward; http://dx.doi.org/10.1136/bmjopen-2017-020162; http://www.ncbi.nlm.nih.gov/pubmed/29487076; https://bmjopen.bmj.com/lookup/doi/10.1136/bmjopen-2017-020162; https://dx.doi.org/10.1136/bmjopen-2017-020162; https://bmjopen.bmj.com/content/8/2/e020162
BMJ
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know