Self-calibrated measurement of ion flow using a fine multihole directional langmuir probe
Japanese Journal of Applied Physics, ISSN: 0021-4922, Vol: 49, Issue: 3 PART 1
2010
- 5Citations
- 6Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
A fine multihole directional Langmuir probe (FM-DLP) has been developed to measure ion Mach number and tested in an electron cyclotron resonance (ECR) plasma. It is found that the FM-DLP can measure the ion Mach number with the same method used for a conventional directional Langmuir probe (DLP). Moreover, the sensitivity of the FM-DLP is almost twice as high as that of the conventional DLP by changing the aspect ratio of the hole that collects ion saturation current. It is also found that the electron saturation current of the FM-DLP is markedly reduced to the level of ion saturation current; thus, the current-voltage characteristics of the FM-DLP become similar to those of an emissive probe, which suggests the emissive-probe-like function of the FM-DLP. We have demonstrated that the FM-DLP can measure the plasma potential, which enables us to determine the calibration factor without other diagnostic tools. Therefore, it is concluded that the FM-DLP has a self-calibration capability for ion flow measurement. © 2010 The Japan Society of Applied Physics.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=77953963897&origin=inward; http://dx.doi.org/10.1143/jjap.49.036101; https://iopscience.iop.org/article/10.1143/JJAP.49.036101; https://dx.doi.org/10.1143/jjap.49.036101; https://validate.perfdrive.com/9730847aceed30627ebd520e46ee70b2/?ssa=b27b4c11-e9e8-4f36-9405-67314151c932&ssb=20639279053&ssc=https%3A%2F%2Fiopscience.iop.org%2Farticle%2F10.1143%2FJJAP.49.036101&ssi=a40fb5e9-cnvj-4a69-9633-65d162d0416c&ssk=botmanager_support@radware.com&ssm=878308797237389793233622142369963413&ssn=5c8fd4493be49481c6d2b855f38b45fbbc8b0900c3c4-8990-4f21-a01b74&sso=b8118f8c-bc564dd29deae53bc663121ca0f1722e3edf8a0bda996090&ssp=39263439491726527204172678214149083&ssq=49910818058685290187829239144650157624429&ssr=NTIuMy4yMTcuMjU0&sst=com.plumanalytics&ssu=&ssv=&ssw=&ssx=eyJyZCI6ImlvcC5vcmciLCJ1em14IjoiN2Y5MDAwMGMxZDc2YmItMzk2MS00N2VjLTlkZGItNjdmYTVhZTY2ODdlNC0xNzI2NTI5MjM5NDUzMjUxMzQ2NjU3LTZiYTkwNmUzZGMyMTRiNzIzMjMyNzgiLCJfX3V6bWYiOiI3ZjYwMDBkNzYzNGE3Ni05ZTRkLTRjMmMtYjJhMC1mYzAzNGMyZjE1MjkxNzI2NTI5MjM5NDUzMjUxMzQ2NjU3LTNlMDRkMDMxZTg5YjMxYTIzMjMyOTkifQ==
IOP Publishing
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know