H conduction in solid-state electrochromic devices analyzed by transient current measurements
Journal of the Electrochemical Society, ISSN: 0013-4651, Vol: 152, Issue: 2
2005
- 8Citations
- 9Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
This paper presents in analysis of transient current measurements on an electrochromic device in order to evaluate the performance of the ion conductor and the average ion mobility in the device. A proton conducting all-thui-film device with WO and hydrated NiO as the working and counter electrodes, respectively, and ZrO, as the ion conductor was studied. Potential reversal experiments were performed, and the resulting transient currents were measured and analyzed. The average proton diffusion coefficient for the whole device was found to be of the order of 10 cm /s and the ZrO layer was shown to be the rate-limiting layer. © 2005 The Electrochemical Society. All rights reserved.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=14744292642&origin=inward; http://dx.doi.org/10.1149/1.1849775; https://iopscience.iop.org/article/10.1149/1.1849775; https://syndication.highwire.org/content/doi/10.1149/1.1849775; https://dx.doi.org/10.1149/1.1849775; https://validate.perfdrive.com/9730847aceed30627ebd520e46ee70b2/?ssa=f7ef29b9-a74e-42c0-ab90-bc7193a06627&ssb=47822279593&ssc=https%3A%2F%2Fiopscience.iop.org%2Farticle%2F10.1149%2F1.1849775&ssi=541f22a0-cnvj-41f5-84a3-f0b98111e6e9&ssk=botmanager_support@radware.com&ssm=498375327083894498894322934397891076&ssn=3a189b8973bf96f8a80387002e7ce4f58c0c0900c3c4-8990-4f21-a84581&sso=a9065f8c-bc564dd29dea144c63b8372c3270ab404e3689969c856344&ssp=31684500251726507434172716602772179&ssq=26677784141127289358229239465943789403718&ssr=NTIuMy4yMTcuMjU0&sst=com.plumanalytics&ssu=&ssv=&ssw=&ssx=eyJ1em14IjoiN2Y5MDAwMGMxZDc2YmItMzk2MS00N2VjLTlkZGItNjdmYTVhZTY2ODdlOS0xNzI2NTI5MjM5NDUzNjEyMTcxOTkxLTkzYTUyOTY2MmI2Nzk1Yjk4ODkxMzUiLCJfX3V6bWYiOiI3ZjYwMDBkNzYzNGE3Ni05ZTRkLTRjMmMtYjJhMC1mYzAzNGMyZjE1MjkxNzI2NTI5MjM5NDUzNjEyMTcxOTkxLTI4NzEzM2I5YTE1ODNmNTk4ODkyMjgiLCJyZCI6ImlvcC5vcmcifQ==
The Electrochemical Society
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know