Successful double-layer metal stents rotational ablation under 2-dimensional and 3-dimensional optical coherence tomography guidance: a case report
BMC Cardiovascular Disorders, ISSN: 1471-2261, Vol: 21, Issue: 1, Page: 173
2021
- 7Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Captures7
- Readers7
Article Description
Background: Stent ablation with rotational atherectomy has been considered a bail-out strategy for the treatment of severe stent underexpansion. Only a few reports have yet shown rotational ablation for double-layer metal struts. Case presentation: We present a case of 80-year-old female patient presented to our hospital because of worsening effort angina. Coronary angiography revealed severe in-stent restenosis in the proximal left anterior descending artery. Optical coherence tomography (OCT) examinations found that severe stenosis occurred at the overlap region with 2-layer underexpanded stents and circumferential calcification beneath them. Under the guidance of 2-dimensional (2D) and 3-dimensional (3D) OCT, we successfully performed percutaneous coronary intervention (PCI) of this lesion after adequate stent ablation, high-pressure balloon dilatation, and subsequent everolimus-eluting stent implantation. The patient recovered well uneventfully and discharged from hospital 7 days later. No restenosis occurred after 12 months. Conclusions: We report a very rare case of in-stent restenosis due to double-layer underexpanded stents. The entire percutaneous coronary intervention procedure was performed step by step under the guidance of high-resolution OCT. Our findings highlight the specific value of 2D and 3D OCT guidance in double-layer stents rotational ablation.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85104226363&origin=inward; http://dx.doi.org/10.1186/s12872-021-01965-z; http://www.ncbi.nlm.nih.gov/pubmed/33849433; https://bmccardiovascdisord.biomedcentral.com/articles/10.1186/s12872-021-01965-z; https://dx.doi.org/10.1186/s12872-021-01965-z
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know