The reliability of a ball-tipped probe for detection of breached versus non-breached pedicle drill tracts in the thoracolumbar and lumbar spine of a canine large breed cadaveric model
BMC Veterinary Research, ISSN: 1746-6148, Vol: 20, Issue: 1, Page: 542
2024
- 1Mentions
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Mentions1
- News Mentions1
- News1
Most Recent News
Study Data from University College Dublin Update Understanding of Veterinary Research (The reliability of a ball-tipped probe for detection of breached versus non-breached pedicle drill tracts in the thoracolumbar and lumbar spine of a canine ...)
2024 DEC 17 (NewsRx) -- By a News Reporter-Staff News Editor at Daily Veterinary News -- Data detailed on veterinary research have been presented. According
Article Description
Background: Spinal stabilization in dogs is challenging, and improper implant placement can result in significant morbidity. Objectives were to evaluate reliability of a ball-tipped probe for detection of breached versus non-breached pedicle drill tracts in a canine large breed cadaveric model. CT scans obtained from T6 to sacrum. Fifty-six pedicles (T7-L7) were randomized to have 1 of 5 modified Zdichavsky drill tracts (non-breached, partial/full medial breach, partial/full lateral breach). All tracts were created using 3D-printed guides. Each pedicle was probed separately by 2 investigators in randomized fashion on 2 occasions, 2 weeks apart. Post-probing CT grading of tracts was performed by one investigator, blinded to probing results. Specificity, sensitivity, positive (PPV) and negative (NPV) predictive values and times to assign grade were compared between surgeons. Results: CT identified 43 non-breached tracts, 7 medial and 5 lateral breaches. One tract was excluded because of guide misplacement. Specificity was 90.1%. PPV for detection of medial and lateral breaches was 80.0% and 57.1%. Sensitivity for medial (grade 2a/2b) and lateral (grade 3a/3b) breaches was 100.0% and 80.0%. NPV was 98.8%. Overall median time to assign grade with probe was 37.5–59.5 s. Both surgeons had very good intraobserver agreement (k,0.823 and 0.812). Interobserver agreement for round 1 was good (k,0.674) and good-to-very good for round 2 (k,0.800). Conclusions: Use of a ball-tipped probe is associated with excellent specificity, excellent sensitivity to detect medial breaches, and good sensitivity to detect lateral breaches. This technique may be useful to confirm integrity of pedicle screw/pin tracts in dogs.
Bibliographic Details
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know