ECNano: A cost-effective workflow for target enrichment sequencing and accurate variant calling on 4800 clinically significant genes using a single MinION flowcell
BMC Medical Genomics, ISSN: 1755-8794, Vol: 15, Issue: 1, Page: 43
2022
- 7Citations
- 30Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations7
- Citation Indexes7
- Captures30
- Readers30
- 30
Article Description
Background: The application of long-read sequencing using the Oxford Nanopore Technologies (ONT) MinION sequencer is getting more diverse in the medical field. Having a high sequencing error of ONT and limited throughput from a single MinION flowcell, however, limits its applicability for accurate variant detection. Medical exome sequencing (MES) targets clinically significant exon regions, allowing rapid and comprehensive screening of pathogenic variants. By applying MES with MinION sequencing, the technology can achieve a more uniform capture of the target regions, shorter turnaround time, and lower sequencing cost per sample. Method: We introduced a cost-effective optimized workflow, ECNano, comprising a wet-lab protocol and bioinformatics analysis, for accurate variant detection at 4800 clinically important genes and regions using a single MinION flowcell. The ECNano wet-lab protocol was optimized to perform long-read target enrichment and ONT library preparation to stably generate high-quality MES data with adequate coverage. The subsequent variant-calling workflow, Clair-ensemble, adopted a fast RNN-based variant caller, Clair, and was optimized for target enrichment data. To evaluate its performance and practicality, ECNano was tested on both reference DNA samples and patient samples. Results: ECNano achieved deep on-target depth of coverage (DoC) at average > 100× and > 98% uniformity using one MinION flowcell. For accurate ONT variant calling, the generated reads sufficiently covered 98.9% of pathogenic positions listed in ClinVar, with 98.96% having at least 30× DoC. ECNano obtained an average read length of 1000 bp. The long reads of ECNano also covered the adjacent splice sites well, with 98.5% of positions having ≥ 30× DoC. Clair-ensemble achieved > 99% recall and accuracy for SNV calling. The whole workflow from wet-lab protocol to variant detection was completed within three days. Conclusion: We presented ECNano, an out-of-the-box workflow comprising (1) a wet-lab protocol for ONT target enrichment sequencing and (2) a downstream variant detection workflow, Clair-ensemble. The workflow is cost-effective, with a short turnaround time for high accuracy variant calling in 4800 clinically significant genes and regions using a single MinION flowcell. The long-read exon captured data has potential for further development, promoting the application of long-read sequencing in personalized disease treatment and risk prediction.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85125863986&origin=inward; http://dx.doi.org/10.1186/s12920-022-01190-3; http://www.ncbi.nlm.nih.gov/pubmed/35246132; https://bmcmedgenomics.biomedcentral.com/articles/10.1186/s12920-022-01190-3; https://dx.doi.org/10.1186/s12920-022-01190-3
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know