PEEP titration: the effect of prone position and abdominal pressure in an ARDS model
Intensive Care Medicine Experimental, ISSN: 2197-425X, Vol: 6, Issue: 1, Page: 3
2018
- 22Citations
- 48Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations22
- Citation Indexes22
- 22
- CrossRef8
- Captures48
- Readers48
- 48
Article Description
Background: Prone position and PEEP can both improve oxygenation and other parameters, but their interaction has not been fully described. Limited data directly compare selection of mechanically “optimal” or “best” PEEP in both supine and prone positions, either with or without changes in chest wall compliance. To compare best PEEP in these varied conditions, we used an experimental ARDS model to compare the mechanical, gas exchange, and hemodynamic response to PEEP titration in supine and prone position with varied abdominal pressure. Methods: Twelve adult swine underwent pulmonary saline lavage and injurious ventilation to simulate ARDS. We used a reversible model of intra-abdominal hypertension to alter chest wall compliance. Response to PEEP levels of 20,17,14,11, 8, and 5 cmHO was evaluated under four conditions: supine, high abdominal pressure; prone, high abdominal pressure; supine, low abdominal pressure; and prone, low abdominal pressure. Using lung compliance determined with esophageal pressure, we recorded the “best PEEP” and its corresponding target value. Data were evaluated for relationships among abdominal pressure, PEEP, and position using three-way analysis of variance and a linear mixed model with Tukey adjustment. Results: Prone position and PEEP independently improved lung compliance (P <.0001). There was no interaction. As expected, intra-abdominal hypertension increased the PEEP needed for the best lung compliance (P <.0001 supine, P =.007 prone). However, best PEEP was not significantly different between prone (12.8 ± 2.4 cmHO) and supine (11.0 ± 4.2 cmHO) positions when targeting lung compliance Conclusions: Despite complementary mechanisms, prone position and appropriate PEEP exert their positive effects on lung mechanics independently of each other.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85056166217&origin=inward; http://dx.doi.org/10.1186/s40635-018-0170-9; http://www.ncbi.nlm.nih.gov/pubmed/29380160; https://icm-experimental.springeropen.com/articles/10.1186/s40635-018-0170-9; https://dx.doi.org/10.1186/s40635-018-0170-9
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know